ZHAO Li,XU Cui-hua,LI Wen-hong,SU Xu.Development of radionuclide parameter database on internal contamination in nuclear emergencies[J].Chinese Journal of Radiological Medicine and Protection,2010,30(3):346-349
Development of radionuclide parameter database on internal contamination in nuclear emergencies
Received:August 18, 2009  
DOI:10.3760/cma.j.issn.0254-5098.2010.03.032基金项目:卫生行业科研专项基金资助项目(200802018)作者单位:100088 北京,中国疾病预防控制中心辐射防护与核安全医学所
KeyWords:Nuclear emergencies  Internal contamination  Radionuclide  Parameter database
FundProject:
Author NameAffiliationE-mail
ZHAO Li National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
XU Cui-hua National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
LI Wen-hong National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
SU Xu National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China suxu@nirp.cn 
Hits: 2589
Download times: 2049
Abstract::
      Objective To develop a radionuclide parameter database on internal contamination in nuclear emergencies.Methods By researching the radionuclides composition discharged from different nuclear emergencies, the radionuclide parameters were achieved on physical decay, absorption and metabolism in the body from ICRP publications and some other publications. The database on internal contamination for nuclear incidents was developed by using MS Visual Studio 2005 C# and MS Access programming language. Results The radionuclide parameter database on internal contamination in nuclear emergency was established.Conclusions The database may be very convenient for searching radionuclides and radionuclide parameter data discharged from different nuclear emergencies,which wonld be helpful to the monitoring and assessment of internal contamination in nuclear emergencies.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9064758  On-line:0

v
Scan QR Code
&et=A90EAC7419FB9B2272464F1AF0D4DCA5AF8B0F2754124A6C8A54F0861B5DD7DAFFCA99AE01A3222E8BF57D650B1220097DD3CCC2617450B921B7126FCE21AA0E2BFE9842B6389F1E83033AB14283006AF683B6D7E9361760AE22605844148FFC&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=84E95DF14EA02ABA3EE496865D331C0F&vid=&iid=38B194292C032A66&sid=C7DDDE86E6286CD9&eid=31125890FF093250&fileno=20100332&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="84E95DF14EA02ABA3EE496865D331C0F";