LI Hai-ying,ZHANG Li,WU Jian-bo,SU Hua-fang,WU Shi-xiu.Cetuximab enhances the radiosensitivity of radioresistant human esophageal squamous carcinoma cell line KYSE-150R[J].Chinese Journal of Radiological Medicine and Protection,2010,30(3):291-294
Cetuximab enhances the radiosensitivity of radioresistant human esophageal squamous carcinoma cell line KYSE-150R
Received:July 13, 2009  
DOI:10.3760/cma.j.issn.0254-5098.2010.03.016
KeyWords:Esophageal carcinoma  Radiosensitivity  Cetuximab
FundProject:
Author NameAffiliationE-mail
LI Hai-ying First Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China  
ZHANG Li 温州医学院附属第一医院放疗科  
WU Jian-bo First Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China  
SU Hua-fang 温州医学院附属第一医院放疗科  
WU Shi-xiu 温州医学院附属第一医院放疗科 wushixiu@medmail.com.cn 
Hits: 3423
Download times: 2225
Abstract::
      Objective To determine the effect of cetuximab (C225) on the radioresistant human esophageal squamous carcinoma cell line KYSE-150R.Methods A radioresistant human esophageal squamous carcinoma cell line KYSE-150R was established by fractionated irradiation. Morphological changes from KYSE-150 to KYSE-150R were observed by phase-contrast microscopy. Karyotype analysis was performed by G-banding. The radiosensitivities were analyzed by colony formation assays.Results The population doubling time of KYSE-150 and KYSE-150R were (23.6±0.2) h and (25.9±0.6) h(t=6.6,P<0.01), respectively. The chromosome number of KYSE-150R was increased and chromosome aberrations were observed from (69.3±1.9) h to (73.7±1.2)h (t=-8.83,P<0.01). The SF2, D0, Dq and N values of KYSE-150R were all higher than those of KYSE-150. After 5 μg/ml of C225 added, the SF2, D0, Dq and N values were significantly decreased as compared to the control. After C225 treatment, the G0/G1 and G2/M phase cells were increased,while S-phase cells decreased(t=-4.478-4.308, P<0.05).Conclusion Cetuximab can enhance the radiosensitivity of radioresistant human esophageal squamous carcinoma cell line KYSE-150R.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9064478  On-line:0

v
Scan QR Code
&et=3E355B084BD51BAE489B98D26C989D47EB5F2F51F4F31A2F18D94D03DF4985F754D28BB7BED8A66E58A538FD98A23A9AFF3579F0BF9C484DB7EC0D6B2B84CED4A9ECD48CF727969ADB6D5AA34EB7FBDFF71F2F2CBBEE61514BCB51CED59F56198B02959AA9090DAE61F02695A0CA82B0B9C9FD63F4BA89C2&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=F63EE01C0184478EDAF1C93BCDCE5F83&vid=&iid=38B194292C032A66&sid=6490F0E20C4B41AD&eid=E39A3F4E3A67639B&fileno=20100316&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="F63EE01C0184478EDAF1C93BCDCE5F83";