ZHANG Xiao-min,PAN Jie,NING Jing,et al.Theoretical design of an epithermal neutron beam for boron neutron capture therapy[J].Chinese Journal of Radiological Medicine and Protection,2010,30(2):116-119
Theoretical design of an epithermal neutron beam for boron neutron capture therapy
Received:June 22, 2009  
DOI:
KeyWords:BNCT  Monte Carlo method  simulation and calculation  Epithermal neutron radiation field
FundProject:国家自然科学基金(10705052)
Author NameAffiliationE-mail
ZHANG Xiao-min Beijing Institute of Radiation Medicine, Academy of Military Medical Sciences, Beijing 100850, China  
PAN Jie Beijing Institute of Radiation Medicine, Academy of Military Medical Sciences, Beijing 100850, China  
NING Jing Beijing Institute of Radiation Medicine, Academy of Military Medical Sciences, Beijing 100850, China  
XIE Xiang-dong Beijing Institute of Radiation Medicine, Academy of Military Medical Sciences, Beijing 100850, China  
YANG Guo-shan Beijing Institute of Radiation Medicine, Academy of Military Medical Sciences, Beijing 100850, China yanggs@nic.bmi.ac.cn 
Hits: 4182
Download times: 2411
Abstract::
      Objective To design a scheme of epithermal neutron beam used for boron neutron capture therapy (BNCT).Methods Based on Tsinghua University experimental reactor and its No.1 passage, five schemes comprised of moderate materials, absorbing materials of thermal neutron and γ shielding materials were designed according to different locations of materials placed in No.1 passage. To select a proper scheme from five schemes, the neutron fluence rate, the neutron dose rate and γ dose rate at exit of beam in each scheme were calculated with Monte Carlo simulating methods and then contrasted with BNCT technique criterion.Results The scheme of epithermal neutron beam meeting technical requirements of BNCT was obtained, in which the thickness of moderate material, absorbing materials of thermal neutron and γ shielding materials are 53.5 cm, 2 mm and 9 cm, respectively.Conclusions The theoretical scheme could provide some reference to realize BNCT on reactor.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565790  On-line:0

v
Scan QR Code
&et=793311EF2E7BAE25DFF15051613D0AA00EB41A40B22AD78BC4D05830D73B8E8C344C3D8554295A11D5F6E4E9BCAFCDD3C65183E0A3C982DEB462BD66F4BEED7009C5E00A9B2F690B0EBD34319B200AFCD79F62ECBF375567&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=65C0DF6061EC96483AA35B61B26DDCDC&vid=&iid=0B39A22176CE99FB&sid=8477411EEDB08A86&eid=EFD65B51496FB200&fileno=20100203&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="65C0DF6061EC96483AA35B61B26DDCDC";