WANG Yun-lai,LIAO Xiong-fei.Measurement of MV CT dose index for Hi-ART helical tomotherapy unit[J].Chinese Journal of Radiological Medicine and Protection,2010,30(1):44-46
Measurement of MV CT dose index for Hi-ART helical tomotherapy unit
Received:July 28, 2009  
DOI:
KeyWords:Helical tomotherapy  CT dose index  Dose length product  Image-guided radiotherapy
FundProject:
Author NameAffiliation
WANG Yun-lai Department of Radiation Oncology, PLA General Hospital, Beijing 100853, China 
LIAO Xiong-fei Department of Radiation Oncology, PLA General Hospital, Beijing 100853, China 
Hits: 3942
Download times: 2692
Abstract::
      Objective To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy. Methods Weighted CT dose index(CTDIW) was measured with PTW TM30009 CT ion chamber in head and body phantoms, respectively, for slice thicknesses of 2, 4, 6 mm with scanned range of 5 cm and 15 cm. Dose length products (DLP) were subsequently calculated. The CTDIW and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols. Results An inverse relationship between CTDI and the slice thickness was found. The dose distribution was inhomogeneous owing to the attenuation of the couch. CTDI and DLP had close relationship with the slice thickness and the scanned range. Patient dose from MVCT was lower than XVI CBCT for head, but larger for body scan. Results CTDIW can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility. Regular measurement should be performed in QA & QC program. Appropriate slice thickness and scan range should be chosen to reduce the patient dose.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565503  On-line:0

v
Scan QR Code
&et=DC44477595533BA7126FC3559CA28267D36E13AA34053E74DFE485E39FC6EA5C6E373529542430B39D58FCF266A38DD4767832638EF031949E5CDBD2629DA38ABB5CF437580958A5&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=E36F1719CAA8AA668E561DF5863D0FCF&vid=&iid=CA4FD0336C81A37A&sid=1AE5323881A5ECDC&eid=D997634CFE9B6321&fileno=20100112&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="E36F1719CAA8AA668E561DF5863D0FCF";