WANG Hao,SHI Pei-ji,ZHOU Xiao-liang,et al.Radiosensitization of nitroindazole derivatives on HeLa cells[J].Chinese Journal of Radiological Medicine and Protection,2010,30(1):20-21
Radiosensitization of nitroindazole derivatives on HeLa cells
Received:February 28, 2009  
DOI:
KeyWords:5-Nitroindazole-3-formyliminodiacetic acid  HeLa cells  Hypoxia  Radiosensiti-zation
FundProject:天津市自然科学基金(08JCYBJC07400)
Author NameAffiliationE-mail
WANG Hao Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China whcams@gmail.com 
SHI Pei-ji Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China  
ZHOU Xiao-liang Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China  
WANG Yan Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China  
TANG Wei-sheng Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China  
Hits: 3953
Download times: 2402
Abstract::
      Objective To investigate the cytotoxicity and radiosensitization of 5-nitroindazole-3-formyliminodiacetic acid on HeLa cells. Methods HeLa cells in exponential growth phase were incubated in culture media with different doses and the survival rate was determined by MTT assay. The survival rate of cells receiving radiation combined with different doses of medicine was compared with that of the control. Results The cytotoxicity of 5-nitroindazole-3-formyliminodiacetic acid on HeLa cells was very low. The drug had hypoxia radiosensitizing effect on HeLa cells. At doses of 0, 6, 12, 24, 48 and 96 μg/ml under hypoxia ,the survival rate were 0.91, 0.87, 0.84, 0.81, 0.76 and 0.60, respectively.At the dosage of 48 and 96 μg/ml,the survival rate were 0.85 and 0.73 under oxygenous). Conclusions 5-Nitroindazole-3-formyliminodiacetic acid has low cytotoxicity and rediosensitizing effect on HeLa cells.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565775  On-line:0

v
Scan QR Code
&et=127E40F7BD15B54261E623AF7B0778C817108F2959E12EFC9B5F1F5C2C571E5508072198127F419BB0B6921FD9969418964C75B6970B54029DCEE2BB92D66AB7&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=31A6A2B879A9AB844CEB5ACA78820004&vid=&iid=CA4FD0336C81A37A&sid=A04140E723CB732E&eid=659D3B06EBF534A7&fileno=20100105&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="31A6A2B879A9AB844CEB5ACA78820004";