QU Ya-jing,ZHENG Jing-chen,LI Gong,NING Jian,CHENG Hai-min,GAO Jian-hua,YE Dao-bin,WANG Hai-yan,LI Guang-xin,JIN Shuai,LI Ren.Experimental study of biochemistry, CT images and pathologic changes in radiation induced liver injury[J].Chinese Journal of Radiological Medicine and Protection,2009,29(5):486-489
Experimental study of biochemistry, CT images and pathologic changes in radiation induced liver injury
Received:October 14, 2008  
DOI:
KeyWords:Radiation-induced liver injury  Tomography  X-ray computation  Biochemical indicator  Pathology
FundProject:
Author NameAffiliationE-mail
QU Ya-jing Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
ZHENG Jing-chen Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
LI Gong Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China dr_gongli@163.com 
NING Jian Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
CHENG Hai-min Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
GAO Jian-hua Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
YE Dao-bin Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
WANG Hai-yan Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
LI Guang-xin Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
JIN Shuai Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
LI Ren Department of Oncology, General Hospital of Armed Police Forces, Beijing 100039, China  
Hits: 3184
Download times: 2131
Abstract::
      Objective To explore the appearance of radiation induced liver disease (RILD) on biochemical indicator, computer tomography(CT) and pathology. Methods Twenty rabbits were randomly divided into 4 groups as control group, 10, 15 and 20 Gy groups administered with semi-liver radiotherapy at different doses. Hepatic function and blood coagulation function indicators were monitored for 3 months after radiation. The appearance of CT images and pathology were observed 3 months post irradiation. Results After irradiation,20 Gy group had 3 rabbits died(3/5), while the other groups had no death. AST, TBIL and DBIL of groups B and C were increased at 1 month post irradiation, while ALP decreased. FbgC and TT were increased at 1 week post irradiation, then decreased to the normal level at 2 week. The CT image appearances were similar among 4 groups ,including no enhancement in artery phase, enhancement of whole liver in portal phase, the veins of liver unclear, and little enhancement in prolonged phase. The pathologic bases of RILD were VOD, collagen fiber aggradation and bile duct inflammation. The changes above-mentioned were more obvious when the radiation dose increased. Conclusions The death rate goes up apparently at the dose of 20 Gy for semi-liver radiotherapy. The doses of 10 and 15 Gy could induce hypohepatia and blood coagulation function to temporarily change. Appearances of CT are weakly enhanced and the veins of liver unclear. When the radiation dose increases, VOD and liver fibrosis become more serious.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9070405  On-line:0

v
Scan QR Code
&et=3B5D9771435A916B26445566CEFC6D4B5F0D15BF8D4D46E83E6470FEE4AFCDB56EC9B25F7B23A069CBFF3DF19F004960DB5EF8135CF42745E2DEDDE045673A81389DA9FBD8658B66CEEED213BFDDBB5442CE0203C894BEDA4AA011BE32A4E2FA6872DC509AFB02B5&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=DE12191FBD62783C&aid=3DD982F2AB4073BF2C6EA7B964C8FC73&vid=&iid=94C357A881DFC066&sid=8C8D895E58E44DBB&eid=F176272DD933A0BB&fileno=20090507&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="DE12191FBD62783C"; var my_aid="3DD982F2AB4073BF2C6EA7B964C8FC73";