ZHANG Xi,CHEN Shao-liang,YANG Xin-rong,LI Hai-qing,YUAN Qing-xi,ZHU Pei-ping,CHEN Yu,HUANG Wan-xia.A preliminary study of phase contrast X-ray imaging with synchrotron radiation[J].Chinese Journal of Radiological Medicine and Protection,2009,29(3):317-319
A preliminary study of phase contrast X-ray imaging with synchrotron radiation
Received:August 01, 2008  
DOI:10.3760/cma.j.issn.0254-5098.2009.03.027
KeyWords:Synchrotron radiation  Phase contrast imaging  Diffraction enhanced imaging  Blood vessel  X-rays
FundProject:国家自然科学基金(30471652)
Author NameAffiliationE-mail
ZHANG Xi Department of Nuclear Medicine, Affiliated Zhongshan Hospital, Fudan University, Shanghai 200032, China  
CHEN Shao-liang Department of Nuclear Medicine, Affiliated Zhongshan Hospital, Fudan University, Shanghai 200032, China Chen.shaoliang@zs_hospital.sh.cn 
YANG Xin-rong 复旦大学中山医院肝癌研究所  
LI Hai-qing 复旦大学中山医院心血管病研究所  
YUAN Qing-xi 中国科学院北京高能物理研究所  
ZHU Pei-ping 中国科学院北京高能物理研究所  
CHEN Yu 中国科学院北京高能物理研究所  
HUANG Wan-xia 中国科学院北京高能物理研究所  
Hits: 3268
Download times: 2300
Abstract::
      Objective To investigate the mouse liver blood vessel images using phase contrast X-ray imaging with synchrotron radiation.Methods 6 female C57BL/6 mice were randomly divided into two groups, 3 mice in each group. In one group, livers excised after ligated arteries, veins and common bile duct. In another group, iodine infused via the portal vein and drained from inferior vena cave until all the blood in the portal veins and hepatic veins was displaced. After infusion, arteries, veins and common bile duct were ligated and livers were excised. ResultsBlood vessel images were clearly produced by diffraction enhanced imaging. This method can discriminate vessels down to about 40 μm in diameter without contrast agent. Using a contrasting agent more details could be produced. In one liver lobe, the entire branch of the portal vein could be clearly produced by one by one phase contrast image from the main axial blood vessels of liver lobe to the nine generation of branching. Conclusions Phase contrast imaging has the advantage of good contrast and high spatial resolution.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069309  On-line:0

v
Scan QR Code
&et=C6BEF307885BECF11B201DFA75FDCE1517879A5340A151E900CCECD9D9039FACD3CE4B867ED17AA6FF849B3F9731A926A89572968BC5A73440A68E9A49B61F9BA52828DD52B53C10C96E46B27E820200&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=DE12191FBD62783C&aid=91E5F9F68700904941DD1646A8721BCF&vid=&iid=38B194292C032A66&sid=E3094127AA4ABC1A&eid=160561E9A96393DE&fileno=20090327&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="DE12191FBD62783C"; var my_aid="91E5F9F68700904941DD1646A8721BCF";