JIAO Ling,ZHANG Wen-yi,DING Yan-qiu,ZHANG Liang-an,HOSHI Masaharu.Estimation of solar radiation and its effects on tooth enamel electron spin resonance dosimetry[J].Chinese Journal of Radiological Medicine and Protection,2009,29(3):306-308
Estimation of solar radiation and its effects on tooth enamel electron spin resonance dosimetry
Received:July 15, 2008  
DOI:10.3760/cma.j.issn.0254-5098.2009.03.023
KeyWords:Solar illuminance  Solar radiation  Tooth enamel  Electron spin resonance  Dosimetry
FundProject:
Author NameAffiliationE-mail
JIAO Ling Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China ljiao.irm@163.com 
ZHANG Wen-yi Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China  
DING Yan-qiu Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China  
ZHANG Liang-an Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China  
HOSHI Masaharu 广岛大学原爆放射线医科学研究所  
Hits: 2962
Download times: 2170
Abstract::
      Objective To investigate solar radiation and its effects on human tooth enamel electron spin resonance (ESR) dosimetry. Methods 11 tooth enamel samples were prepared by mechanical method.The intensity of solar illuminance was measured with a light meter, the measured illuminance was converted to insolation using a coefficient. Summation of solar radiation was evaluated.Enamel samples were exposed to 6060Co γ rays followed by sunlight on sunny days, and ESR spectra were scanned after different exposure. Results The conversion coefficient for measured illuminance to insolation was (8.67±0.22) W·m-2klx. The integrated solar radiation to the samples was (580±16) MJm2. Solar exposure also caused dosimetric signal. The perpendicular component of dosimetric signal increased linearly with the amount of solar radiation, another signal close to background tended to saturation. Conclusions The average effect of the solar radiation on the signal was estimated by dose equivalent γ ray irradiation as (7.7±1.4) mGy·MJm2. Signal near to background may be used to recognize the effect of solar radiation on the enamel, and estimate external dose accurately.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9077367  On-line:0

v
Scan QR Code
&et=EC9A7F1C2771EE5020351210AECD1E8F4BEA5D9A2D01D36263D08BEB97144467365D0C49D9D39ED5E8B876CA342728461A1EA272AF3CA76FA2B31C3AD63EB7EE7509B01829B54369C2002FE78223BB150E0335584976681466E91CCF81BD32E6&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=DE12191FBD62783C&aid=E02BDE2CB5D11064586D20C72C9A9692&vid=&iid=38B194292C032A66&sid=31BCE06A2FD82A16&eid=51C74DF6A16DA45B&fileno=20090323&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="DE12191FBD62783C"; var my_aid="E02BDE2CB5D11064586D20C72C9A9692";