LI Yu-wen,FENG Jiang-bin,LU Xue.Preliminary detection of expression changes of human mitochondrial COXI, ND1 and ND6 gene induced by 60Coγ-rays[J].Chinese Journal of Radiological Medicine and Protection,2009,29(2):125-128,142
Preliminary detection of expression changes of human mitochondrial COXI, ND1 and ND6 gene induced by 60Coγ-rays
  
DOI:10.3760/cma.j.issn.0254-5098.2009.02.001
KeyWords:60Coγ-rays  Human lymphoblastoid cell line  Mitochondrion  Gene expression
FundProject:国家自然科学基金(30870749, 30570551);北京市自然科学基金(7053073)
Author NameAffiliationE-mail
LI Yu-wen National Institute for Radiological Protection, China CDC, Beijing 100088, China  
FENG Jiang-bin National Institute for Radiological Protection, China CDC, Beijing 100088, China  
LU Xue National Institute for Radiological Protection, China CDC, Beijing 100088, China  
陈德清 National Institute for Radiological Protection, China CDC, Beijing 100088, China  
刘青杰 National Institute for Radiological Protection, China CDC, Beijing 100088, China qjliu@nirp.cn 
Hits: 2958
Download times: 1969
Abstract::
      Objective To explore the changes of human mitochondrial COXI, ND1 and ND6 genes expression induced by ionizing irradiation.Methods Changes of human COXI, ND1 and ND6 gene expression were detected by RT-PCR and Real-time PCR 8 h after the irradiation in human lymphoblastoid cell lines, which were exposed to 1-10 Gy 60Coγ-rays. And the dose-effect relationships between expression changes of the genes and the doses were analyzed. The changes of these three genes expression were also analyzed at different post-radiation time-points between 0.5 h and 72 h after irradiation of 5 Gy in order to explore the time-effect.Results The expression of three genes COXI, ND1 and ND6, showed either the dose-effect or the time-effect after irradiation. The gene expression levels of three genes up-regulated generally and the peak change time-point was 4 h after irradiation.Conclusion Ionizing radiation might induce the changes of mitochondrial gene expression, and the gene expression level is up-regulated.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9072164  On-line:0

v
Scan QR Code
&et=05856B6FACD30C9974ABD13045AB96F7AA708E67AD79F5BDAD99F00DD33747EA3D1A192CB78A5D3D2F8AA5D35E6A0F751897FB22311ED1C1FCCE3770DCB3D9513A9A3E75E8FE18DC9621646FB552EC1FA055AB385DEC0CF5D8E58CF8E8BBAD01A151EFC8C006BA6125F0EC5886287CBC73670A057781151CB9DBAEB55DB3A0F7&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=DE12191FBD62783C&aid=F9D18DC6BD5DB32464B43074E3D5B891&vid=&iid=0B39A22176CE99FB&sid=F122871CC7EC92DC&eid=28B31B7FBB4AE2BD&fileno=20090201&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="DE12191FBD62783C"; var my_aid="F9D18DC6BD5DB32464B43074E3D5B891";