LI Jian-bin,WANG Jin-guo,LU Jie,et al.The study of target delineation and target movement of whole breast assisted by active breathing control in intensity modulated radiotherapy after breast conservative surgery[J].Chinese Journal of Radiological Medicine and Protection,2009,29(1):58-60
The study of target delineation and target movement of whole breast assisted by active breathing control in intensity modulated radiotherapy after breast conservative surgery
Received:June 07, 2008  
DOI:10.3760/cma.j.issn.0254-5098.2009.01.018
KeyWords:Active breathing control  Breast  Intensity-modulated radiotherapy  Target delineation  Target displacement
FundProject:国家自然科学基金资助项目(30870742);山东省科技攻关资助项目(01213014)
Author NameAffiliationE-mail
LI Jian-bin Department of Radiation Oncology, Shandong Cancer Hospital, Jinan 250117, China lijianbin@msn.com 
WANG Jin-guo 宁波市医疗中心李惠利医疗放疗科  
LU Jie 250117 济南, 山东省肿瘤医院物理室  
YU Jin-ming Department of Radiation Oncology, Shandong Cancer Hospital, Jinan 250117, China  
MA Zhi-fang Department of Radiation Oncology, Shandong Cancer Hospital, Jinan 250117, China  
SUN Tao 250117 济南, 山东省肿瘤医院物理室  
GUO Shou-fang 250117 济南, 山东省肿瘤医院CT室  
Hits: 4120
Download times: 2517
Abstract::
      Objective To explore the influence of different delineators and different delineating time on target determination of the whole breast and to explore intrafraction and interfraction target displacements of the breast on moderate deep inspiration breathing hold (mDIBH) assisted by active breathing control (ABC) after breast conservative surgery. Methods Twenty patients received primary CT-simulation assisted by ABC to get five sets of CT image on the three breathing condition which included one set from free breath (FB),two sets from mDIBH and two sets from deep expiration breathing control (DEBH). After radiotherapy with ten to fifteen fractions, the repeat CT-simulation was carried out to get the same five sets of CT image as the primary CT-simulation. The whole breast target were delineated at different time by the same delineator and delineated respectively by five delineators on the first set of CT images got with mDIBH from the primary CT-simulation,and to compare the influence of delineator and delineating time on the whole breast target. The total silver clips in the cavity were marked respectively on the two sets of CT images got with mDIBH from the primary CT-simulation, and to compare the intrafraction displacement of geometric body structured by the total of silver clips. The two ribs near the isocentric plane of the breast target were delineated respectively on two sets of the mDIBH CT image from the primary CT-simulation and on one set of the mDIBH CT image from the repeat CT-simulation, and comparing the movement of the point of interest (POI) of the ribs delineated to get the value of intrafraction and interfraction thoracic expansion. Results There was not statistically significant between the four volumes of whole breast targets delineated by the same delineator at different time, but with statistics significant between the volumes of whole breast target delineated by the different delineators(F=19.681,P=0.000). There was not statistically significant between the intrafraction displacements of the POI of the geometric body at each direction, and with no statistically significant between intrafraction displacements of the POI of the ribs delineated on the same mDIBH condition. There was not statistically significant between the interfraction displacements of the POI of the ribs delineated.Conclusion The influence of different delineators on the whole breast target is statistically significant. The difference of displacement of the breast target with the same mDIBH condition assisted by ABC at the different direction is not statistically significant.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11566332  On-line:0

v
Scan QR Code
&et=08841D4249DD84C52F787C50AC33A72037CEDEB3638E0A9BFD6288D9BCC6B4064E802DA1CA274F7617D7AA817A54658AE2DB3D981ED3BEF55BA8F4CE6B8FF6361E2C7786E362D795172B17B2A4EDB9B4334C8F51719F090CAC7A9AC2E594CB34C6FDC5F13B34EE21BB0E53A22E9D1F3BBF369FD6D777C21B3F9C77F4BC63F63ADC1C3D50EA6AFB657AB4AB35BE0CF97960A9A0AE292BCCACA2D3B91AF3470A8D28B860427EC39DF1E7BEF7585A53114A&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=DE12191FBD62783C&aid=CB02F127521A0A9F4CB7F5DB866CD20A&vid=&iid=CA4FD0336C81A37A&sid=9FFCC7AF50CAEBF7&eid=BFE7933E5EEA150D&fileno=20090118&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="DE12191FBD62783C"; var my_aid="CB02F127521A0A9F4CB7F5DB866CD20A";