SONG Tie-li,ZHENG Lei,LI Ya-gang.125I seed fixity after implantation in parotid region[J].Chinese Journal of Radiological Medicine and Protection,2008,28(5):517-519
125I seed fixity after implantation in parotid region
Received:September 15, 2007  
DOI:
KeyWords:125I seed implantation  Fixity  Treatment planning system  Parotid
FundProject:
Author NameAffiliationE-mail
SONG Tie-li Department of Maxillofacial Surgery, School of Stomatology, Peking University, Beijing 100081, China songironsand@163.com 
ZHENG Lei Department of Maxillofacial Surgery, School of Stomatology, Peking University, Beijing 100081, China  
LI Ya-gang 北京大学第一医院放射治疗科  
黄明伟 Department of Maxillofacial Surgery, School of Stomatology, Peking University, Beijing 100081, China  
张杰 Department of Maxillofacial Surgery, School of Stomatology, Peking University, Beijing 100081, China  
张建国 Department of Maxillofacial Surgery, School of Stomatology, Peking University, Beijing 100081, China  
Hits: 2917
Download times: 1790
Abstract::
      Objective To observe the fixity of 125I seed after implantation in parotid region. Methods Ten patients treated with 125I seed interstitial brachytherapy in parotid were randomly selected. Within one week after the treatment, two plane radiographs were taken by radiotherapy simulator and 125I seed was counted. All plane dosimetry analysis were performed by treatment planning system. The areas surrounded by 50%,100% and 150% of prescription dose curve and dose equality index were calculated. Two months after the treatment, the same examination were repeated and were compared with t test. Results The number of seeds was equal in two examination. There were no significant differences in two examinations either for the areas surrounded by 50%,100% and 150% of prescription dose curve or for the dose equality index. Conclusions The position of 125I seed after implantation in parotid region is quite fixable, which can ensure the curative effect.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9062735  On-line:0

v
Scan QR Code
&et=FCD189AE5E1921B9B8DD0696C98947A4565D5C833244A4C9A4EF12E7EF980F0B45B2ADD7238E9C338891ECA27B7AC3E091E85A9BDD6A39A1C0D2E8E5D031DB1B87BD7ED49A9FEA43&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=67289AFF6305E306&aid=C00C4C25F5816DBA19831A7D5784625A&vid=&iid=94C357A881DFC066&sid=5A751AE9FA58A3FB&eid=89389F643CA3F778&fileno=20080523&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="67289AFF6305E306"; var my_aid="C00C4C25F5816DBA19831A7D5784625A";