LIU Yu-long,PU Wang-yang,BAO Yong-di,et al.Medical treatment of two cases with internal contamination combined with skin contamination of 131I[J].Chinese Journal of Radiological Medicine and Protection,2008,28(5):459-461,465
Medical treatment of two cases with internal contamination combined with skin contamination of 131I
Received:May 08, 2008  
DOI:
KeyWords:131I  Internal contamination of radionuclides  Skin contamination of radionuclides  Dose estimation  Medical treatment
FundProject:
Author NameAffiliationE-mail
LIU Yu-long Second Affiliated Hospital of Soochow University, Suzhou 215004, China yulongliu2002@yahoo.com.cn 
PU Wang-yang Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
BAO Yong-di Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
李元 Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
张玉松 Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
戴宏 Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
周丽英 Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
周剑影 Second Affiliated Hospital of Soochow University, Suzhou 215004, China  
Hits: 3867
Download times: 2080
Abstract::
      Objective To introduce the accident course and clinical characteristics of two cases with internal contamination combined with skin contamination of 131I, and to present the dose estimation, medical treatment and their follow-up study which will be helpful for the similar cases in medical emergency. Methods Whole body count measurement apparatus was used for radioactivity monitoring and dose was estimated and calculated by using INDO 2000 software. Medical treatment included asking and physical examination, decontamination of contaminated skins and combined therapies. The laboratory examination of routine examination, tumor markers, and conventional chromosome aberration and micronucleus analysis were included in medical follow-up. Results The committed effective doses evaluated by INDO 2000 software were 0.10-0.19 Sv and 0.023-0.046 Sv for two cases respectively. 2.0-3.8 Sv and 0.46-0.89 Sv were the committed doses equivalent of hypothyroid for them separately. Decontamination and combined therapies were effective methods and there was no obvious abnormity in a 4-year medical follow-up. Conclusions Dose estimation, medical treatment and follow-up study for two cases with an internal-and-skin combined contamination of 131I has been properly performed.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11566792  On-line:0

v
Scan QR Code
&et=32083DF85146B5818DF8C93A9C67468CA4575BDD2BE43527B41DDCD124B1B60B705A6308B6F0596075F02C12A6A6C287BE52CCD81B0921B5E8DA02CDADBE6CC38CCE26B7FFD7682A5C9D707521B83925A23540E8DA195A30FD91A6A20061920D7155921ED84CE10948AE45825AABAC1F&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=67289AFF6305E306&aid=9FFCE6C2FC0EF9CCB7FCCDEC0FA66A90&vid=&iid=94C357A881DFC066&sid=3389C664025A98F9&eid=88B429CACC82F267&fileno=20080507&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="67289AFF6305E306"; var my_aid="9FFCE6C2FC0EF9CCB7FCCDEC0FA66A90";