ZHAO Pan,SONG Gang,LIN Hui.Implementation of outside contour extraction based on CT number in making plan of accurate radiotherapy[J].Chinese Journal of Radiological Medicine and Protection,2007,27(5):463-466
Implementation of outside contour extraction based on CT number in making plan of accurate radiotherapy
Received:November 02, 2006  
DOI:
KeyWords:Accurate radiotherapy  CT number  Outside contour extraction  W/L algorithm
FundProject:国家“973”计划项目(2006CB708307),安徽省自然科学基金项目(070413081)
Author NameAffiliation
ZHAO Pan Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
SONG Gang Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
LIN Hui Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
吴爱东 Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
黄晨昱 Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
吴宜灿 Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 
Hits: 2752
Download times: 2080
Abstract::
      Objective To supply more precise outside contour for dose calculation and 3D reconstruction in accurate radiotherapy. Methods With the W/L algorithm, the automatic outside contour extraction based on CT number was realized, after the relation between CT number and the tissue of human body had been analyzed. Results The speed in this way was 2.5 times greater than the traditional one with the same results. Conclusions The method of outside contour extraction based on CT number need not to be bivalued, and the precise outside contour of human body can be obtained quickly. This method might have good application in accurate radiotherapy.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057499  On-line:0

v
Scan QR Code
&et=5D0317C242490918B8F014C46E06E59D3257DB1DB8DFAE4A81789B030B2FA139EA98B3B49409A22135C155455663BCBBEFD7B2C478D06BA57B5B86F5E5C69D76B6D0A283AC1D183A886C8C1B5893392168CEA1B6A87083AE427C9535A6D8B880454DFF16B6570290&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=A732AF04DDA03BB3&aid=308A5963270DDEEA8CFE2F50057FBBF3&vid=&iid=94C357A881DFC066&sid=788931E6318420A3&eid=4D4C81DBA842B7BD&fileno=20070516&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="A732AF04DDA03BB3"; var my_aid="308A5963270DDEEA8CFE2F50057FBBF3";