LÜ Hui-min,JIA Ke-jun,ZHENG Hui,et al.Effect of thorium and rare earth mixed dust on cytokines and haematological indexes of occupational personnel[J].Chinese Journal of Radiological Medicine and Protection,2007,27(3):260-262
Effect of thorium and rare earth mixed dust on cytokines and haematological indexes of occupational personnel
Received:November 16, 2006  
DOI:
KeyWords:Mine dust exposure  Immunological function  Cytokines  Hematology
FundProject:科技部科研院所社会公益研究专项项目(2005DIB1J087),公共卫生专项经费(54006-0104)
Author NameAffiliationE-mail
LÜ Hui-min National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
JIA Ke-jun 包钢劳动卫生职业病防治研究所  
ZHENG Hui National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
涂序珉 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
刘玉飞 包钢劳动卫生职业病防治研究所  
甄荣 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
张伟 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
张翠兰 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
王春燕 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
郝述霞 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China  
苏旭 National Institute for Radiologcal Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China suxu@nirp.cn 
Hits: 3562
Download times: 2358
Abstract::
      Objective To study the effects of thorium and rare earth mixed dust on cytokines and haematological indexes of occupational personnel exposed to low dose radiation.Methods Serum IL-2, IL-6 and TNF were analysed by radioimmunoassay and haemocytological indexes were estimated by automatic blood corpuscle analysator.Results Serum IL-2 were (2.267±1.032) pg/ml and (4.608±1.411) pg/ml for exposure and non-exposure groups respectively; IL-6 were (66.55±27.22) pg/ml and (124.3±56.32) pg/ml respectively, showing that levels of IL-2 and IL-6 for exposure groups were lower than that of normal values and decreased than non-exposure groups. Activities of TNF were (0.96±0.33) ng/ml and (0.84±0.35) ng/ml, respectively.It was shown that TNF level of exposure group was obviously higher than that of non-exposure group, although no significant difference was found between two groups for normal reference values. Examination of 14 haematological indexes, among them, 5 indexes of exposure group showed significantly difference compared with those of non-exposure group. Conclusion Thorium and rare earth mixed dust might affect some immunological function and haematological indexes of occupational personnels chronically exposed to low dose radiation.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11566766  On-line:0

v
Scan QR Code
&et=FF4EC6B96077DFE7BF3F0945E94A7B7C6E734645F5035D05E844B8CFEDD172E81764CAFCB286D81A5DC0057959D03B37E47D7AB93024DBD0BC5728F4CFC707EE9AF93ED3BD6F272DCE16A4452C5A27DD7EFE162E508EFECD1E053CC9E7A750CF45ED6175006A6D232C2E0D4F82657D64&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=A732AF04DDA03BB3&aid=318485F2B3976918CB71BBCEDB2CFB91&vid=&iid=38B194292C032A66&sid=89AC6B0ADBEA2741&eid=30897FA31CA3354D&fileno=20070319&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="A732AF04DDA03BB3"; var my_aid="318485F2B3976918CB71BBCEDB2CFB91";