LIU Jian-xin,DENG Gang,YIN Xiao-ming.Importance of automatic tube current technology with mutli-detector CT in chest test[J].Chinese Journal of Radiological Medicine and Protection,2007,27(2):191-192
Importance of automatic tube current technology with mutli-detector CT in chest test
Received:February 25, 2006  
DOI:
KeyWords:CT  Automatic tube current technology  Radioprotection
FundProject:
Author NameAffiliation
LIU Jian-xin The Imaging Department of Coal Mining General Hospital of Beijing 
DENG Gang The Imaging Department of Coal Mining General Hospital of Beijing 
YIN Xiao-ming The Imaging Department of Coal Mining General Hospital of Beijing 
杨凤芹 The Imaging Department of Coal Mining General Hospital of Beijing 
Hits: 2940
Download times: 1889
Abstract::
      Objective To explore the importance of automatic tube current technology of multi-detector CT in chest test. Methods Each group of study and control include 30 cases. The technology of auto tube current(noise index=10.00) and fixed tube current(200 mA) were performed separately. Comparision with image noisiness and detail to show and information of dose was made. Results There is no significant difference(P=0.136,0.289,0.176) between both groups in CT value in the supra-aortic arch,tracheal prominence and supra-diaphragmatic level respectively with no significant difference (P=0.121) of background SD in supra-aortic arch level.There is significant difference(P=0.001,0.000) of background SD in tracheal prominence and supra-diaphragmatic level respectively. There is no significant difference between study and control groups in demonstration of grade and morphology in pulmonary micro-vessels,bronchiole and interlobar fissure etc.Linear artifact was found in both study and control group in supra-aortic arch level,but more slices with artifact and more noise granule in study group. CTDIvol and DLP were about 1/3 of control group. Conclusions Utilization of CT auto tube current can ensure the image quality and reduce the dose of patients.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9063987  On-line:0

v
Scan QR Code
&et=EAA7E8C88F0F10015C834BD9F49637AE602860E68025193A74B4AC5C18ABFB987B2EDB0821D7BA4E22159B185093DA3BF500A5CDAC6940D55B0D09CCE91CAA32EAC0ACBF99399AD145A657D3280E398182CC66B3CDC1FB5E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=A732AF04DDA03BB3&aid=BD94815F4FF2402A14409120D1F37865&vid=&iid=0B39A22176CE99FB&sid=AC1578C6BB9EBDEF&eid=C29816B2656377A7&fileno=20070231&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="A732AF04DDA03BB3"; var my_aid="BD94815F4FF2402A14409120D1F37865";