FU Zhi-chao,CHENG Hui-hua,LAI Hong-bin.Three dimensional conformal radiotherapy for 125 cases with gliomas postoperation[J].Chinese Journal of Radiological Medicine and Protection,2007,27(2):164-166
Three dimensional conformal radiotherapy for 125 cases with gliomas postoperation
Received:April 17, 2006  
DOI:
KeyWords:Glioma/radiotherapy  Radiotherapy  Conformal  Prognosis
FundProject:
Author NameAffiliation
FU Zhi-chao Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
CHENG Hui-hua Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
LAI Hong-bin Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
林贵山 Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
李东石 Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
原锦 Department of Radiotherapy, Fuzhou General Hospital of Nanjing Military Command, Fuzhou 350025, China 
Hits: 2192
Download times: 1844
Abstract::
      Objective To evaluate the clinical results and side effect of Three dimensional conformal radiotherapy (3DCRT) for gliomas postoperation. Methods From July 2002 to July 2003, 125 patients with gliomas postoperation were randomly divided in three dimensional conformal radiotherapy (3DCRT) and conventional therapy(CT) groups. The 63 patients in 3DCRT group were received three dimensional conformal therapy constantly in 2.0-2.5 Gy/f, 5 fractions a week to a total dose of 50-60 Gy in 5-6 weeks. The 62 patients in CT group were received conventional radiotherapy in 1.8-2.0 Gy/f, 5 fractions a week to a total dose of 50-60 Gy in 4-6 weeks. Radiotherapy starred within 2 weeks to 1 month after surgery. The local control rate, survival rate and side effects were compared in the two groups. Results The 1-,2-and 3-year local control rates were 77.9%,66.5% and 57.7% in 3DCRT group, 67.4%,47.9% and 37.9% in CT group (χ2=4.65,P<0.05). The 1-,2-and 3-year survival rates were 81.0%,71.3% and 63.2% in 3DCRT group, 80.6%,58.1% and 44.8% in CT group (χ2=4.42, P<0.05). The incidence rate of cerebral edema was 33.3% in 3DCRT group and 51.6% in CT group(χ2=12.09,P=0.001). Conclusions The local control rate and survival rate of patients with gliomas postoperation treated by 3DCRT is superior to CT. However, the incidence rate of side effect in 3DCRT group is lower than that in CT group.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057362  On-line:0

v
Scan QR Code
&et=DB604C34F40EDE680AA090E15DD6EC27A048F993E87EBB2EA5963C0862D7CC271308FFA0133D4B4A1F77DA67E8DA7D50F42C8905BFAA739FD6FA1BB9FE429E633806F75C25C1F0D419E8ABED793129972E1718D8DC590916&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=A732AF04DDA03BB3&aid=26FC90AB37DDEC094269DB695879FE2C&vid=&iid=0B39A22176CE99FB&sid=F260CE035846B3B8&eid=43608FD2E15CD61B&fileno=20070219&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="A732AF04DDA03BB3"; var my_aid="26FC90AB37DDEC094269DB695879FE2C";