LI Jie-qing,YU Jin-ming,WANG Qing-wei.Chromosome aberration and HPRT gene loci mutant frequency in peripheral blood lymphocytes in nasopharyngeal carcinoma patients before and after radiotherapy[J].Chinese Journal of Radiological Medicine and Protection,2007,27(2):157-158
Chromosome aberration and HPRT gene loci mutant frequency in peripheral blood lymphocytes in nasopharyngeal carcinoma patients before and after radiotherapy
Received:April 20, 2006  
DOI:
KeyWords:Radiotherapy  Chromosome aberration  HPRT gene loci mutant frequency
FundProject:
Author NameAffiliationE-mail
LI Jie-qing Tianjin Medical University , Tianjin 300070, China.  
YU Jin-ming 山东省肿瘤医院放疗科 jn7984729@public.jn.sd.cn 
WANG Qing-wei 山东大学齐鲁医院肿瘤中心  
刘伟 山东省医学科学院放射医学研究所  
Hits: 2749
Download times: 1686
Abstract::
      Objective To study the radiation injury in periphery blood lymphocytes in nasopharyngeal carcinoma patients and explore the possibility of radiation biological dosimeter by chromosome aberration and HPRT gene loci mutant frequency . Methods Before and after the patients with nasopharyngeal carcinoma accepting radiotherapy, chromosome aberrations and HPRT gene loci mutant frequencies of lymphocytes in periphery blood were investigated. Results Chromosome aberrations and HPRT gene loci mutant frequencies of lymphocytes in patients before radiotherapy were statistically higher than those in controls and lower than those in patients after radiotherapy. Conclusions The combined investigation of chromosome aberrations and HPRT gene loci mutant frequencies in periphery blood may be expected to be radiation biological dosimeter to judge the radiotherapy-induced genetic damage .
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057624  On-line:0

v
Scan QR Code
&et=B836F50C881A9205E24489FFD7D4E9BDCC98C6984F1743A95FD33011AA09CABBE558C9F8A72E35DD178C55BA154262F413A49E7C88F3557B88FE2BE2CAD73E3F662447D1FDB29C609AB8F4059B652207F4D16348EECCE6B19F4E07C093943AD5C3CF14CB01942225AF172329BB26C0E898ADB34DAFBD5590752D9DC07E7A5CFA5FBC1EC9FAAF7FEF20A543F39D24EAB9E20C79C913CC0F58485903AFBA2BFE1E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=A732AF04DDA03BB3&aid=D9628106FF5C9816BF71802C501B4FDB&vid=&iid=0B39A22176CE99FB&sid=0B4F496D54044D86&eid=4C100B7696CE9E24&fileno=20070216&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="A732AF04DDA03BB3"; var my_aid="D9628106FF5C9816BF71802C501B4FDB";