XIONG Zhuang,WANG Jian-hua,YU Yong-qiang.Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility[J].Chinese Journal of Radiological Medicine and Protection,2006,26(6):614-616
Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility
Received:December 28, 2005  
DOI:
KeyWords:Phase Contrast Imaging  X-ray  Synchrotron Radiation
FundProject:
Author NameAffiliation
XIONG Zhuang Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China
 
WANG Jian-hua Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China
 
YU Yong-qiang 安徽医科大学附属医院放射科 
蒋诗平 中国科学技术大学同步辐射实验室 
陈阳 中国科学技术大学同步辐射实验室 
田玉莲 中国科学院高能物理研究所 
Hits: 2514
Download times: 1774
Abstract::
      Objective To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9076775  On-line:0

v
Scan QR Code
&et=05856B6FACD30C99AAF724D5AA8F8150F9CCC4BC65299158D92C427DB2B1F7E5D9DD0DF1A35435446FDA97948DAA6D0FCB8C608823EE0A75C2646DC7219D5CC05572A067DCC55BCFE405029BF7F742C77C78691AD7D2CF0E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=37904DC365DD7266&aid=38EF95DACF42359C&vid=&iid=B31275AF3241DB2D&sid=2C20277AC27E4821&eid=984BD2F4D19B9D1C&fileno=20060628&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="37904DC365DD7266"; var my_aid="38EF95DACF42359C";