WANG Peng-cheng,ZHANG Fu-li,LI Shi-jun.Comparison of two kind of flat panel detector radiography system:imaging quality versus exposure dose[J].Chinese Journal of Radiological Medicine and Protection,2006,26(4):401-404
Comparison of two kind of flat panel detector radiography system:imaging quality versus exposure dose
Received:January 08, 2006  
DOI:
KeyWords:Digital radiography  Flat panel detector  Exposure dose
FundProject:
Author NameAffiliation
WANG Peng-cheng Department of Radiology, Taishan Medical College, Taian 271016, China 
ZHANG Fu-li 军事医学科学院放射与辐射医学研究所 
LI Shi-jun 苏州大学放射医学与公共卫生学院 
Hits: 3161
Download times: 1952
Abstract::
      Objective To compare the imaging quality at different exposure settings for amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel detector digital radiography system with amorphous Selenium (a:Se) flat panel detector digital radiography system. Methods The images of contrast-detail phantom (CDRAD 2.0) were taken at different exposure settings for two digital radiography systems. Four independent observers read the images and calculated the IQF for different dose settings. The detectability of two system for contrast and detail was analysed using ANOVA. A ROC analysis was performed with TRG phantom in different exposure settings. The statistical significance was evaluated using the Wilcoxon test. Results There was a significant difference of IQF and Az values of ROC between the two systems at lower dose exposure, which ensured a better image quality concerning contrast and detail detectability. Higher dose exposure provided similar results for both systems. Conclusion The a:Si flat panel digital radiography system proved to be superior to a:Se flat panel digital radiography system at low dose settings. Without the image quality lost, the patient dose might be reduced if an a:Si system was used.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9060103  On-line:0

v
Scan QR Code
&et=8C10CEA789A144B8C619E1A00DC6A0B7CB048C5878C68940194596253A53EB2C118398B6AA3BE852C5905A58940215A2AB0CD7E76CACB9A8703CCB1557B176A7069FC60235E41B8394E851A701F6D2203BDD2465ED7FE543DE9890B26D8C6A0C68DCB4932C04B83C&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=37904DC365DD7266&aid=DDAE51E0D2B60499&vid=&iid=E158A972A605785F&sid=238BD7580EFCC5AE&eid=B79ACB6EBBFC9730&fileno=20060433&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="37904DC365DD7266"; var my_aid="DDAE51E0D2B60499";