YU Jian-ming,LEI Zi-qiao,KONG Xiang-chuang.Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging[J].Chinese Journal of Radiological Medicine and Protection,2006,26(4):399-400,407
Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging
Received:November 23, 2005  
DOI:
KeyWords:Direct digital radiography  Dual energy subtraction  Rib imaging
FundProject:
Author NameAffiliation
YU Jian-ming Department of Radiology of Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China 
LEI Zi-qiao Department of Radiology of Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China 
KONG Xiang-chuang Department of Radiology of Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China 
Hits: 2621
Download times: 1756
Abstract::
      Objective To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results Among the total of 200 patients, there are 50 cases of rib calcification,7 cases of rib destruction,22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9065815  On-line:0

v
Scan QR Code
&et=CA2056D32C3CC34237BA9D7B270FA5C2FE8FC6D8DDB36B23E3BB1E17E07B23D626D5425BC2892D4D1F3CF0EF5B3C639CE85CB547103BC6D0937729393B9E7F920F49D55D5879D96F465129893BE0051679DCEAE65BBF5D0DA63F01D95FC92B29BA2406E692BEA4E4&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=37904DC365DD7266&aid=C48725001835F98A&vid=&iid=E158A972A605785F&sid=87545994EC2C1F12&eid=C8B327D89D82484F&fileno=20060432&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="37904DC365DD7266"; var my_aid="C48725001835F98A";