ZHANG Qing,LI Wen-hong,ZHANG Jing.The estimates of radionuclide intake and committed effective dose based on gamma spectrometric analysis[J].Chinese Journal of Radiological Medicine and Protection,2006,26(2):168-170
The estimates of radionuclide intake and committed effective dose based on gamma spectrometric analysis
Received:April 12, 2005  
DOI:
KeyWords:Gamma spectrometry  Internal contamination  Intake  Committed effective dose  Excretion
FundProject:
Author NameAffiliation
ZHANG Qing National Institute for Radiological Protection, China CDC, Beijing 100088, China 
LI Wen-hong National Institute for Radiological Protection, China CDC, Beijing 100088, China 
ZHANG Jing National Institute for Radiological Protection, China CDC, Beijing 100088, China 
赵力 National Institute for Radiological Protection, China CDC, Beijing 100088, China 
周强 National Institute for Radiological Protection, China CDC, Beijing 100088, China 
徐翠华 National Institute for Radiological Protection, China CDC, Beijing 100088, China 
Hits: 2725
Download times: 2134
Abstract::
      Objective To establish a way to measure intake of radionuclides and estimation of committed effective dose based on gamma spectrometry analysis. Methods Using gamma spectrometry to measure radionuclides excretion feces and urine of internally contaminated persons. The measured values are to be used to estimate the in take of radionuclides and committed effective dose. The calculation process was performed by a computer code. Result This method can be used to estimate internal contamination and the coputer code may provide quick and exact results. Conclusion This research provides a rapid method to measur and estimate radionuclides causing internal contamination, and it may meet the needs in emergency cases.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9075360  On-line:0

v
Scan QR Code
&et=2D79AC743E5FD1F1DE54A4C28D84E31BADF68B4232417C5131A41415A34C079298BB42469DBB8833826DD008C9B17E70C7999E8F00B0E99378D3AD648FBC820CA38DF7B4261CC9254C7B83B3904907F664B7495C64E134C254517F8DF6F15B7959DEA4BFA113801E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=37904DC365DD7266&aid=249B86316B68BC83&vid=&iid=0B39A22176CE99FB&sid=BBF7D98F9BEDEC74&eid=C5F8B8CB20F1B3D8&fileno=20060224&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="37904DC365DD7266"; var my_aid="249B86316B68BC83";