QIAN Xin,HAN Yun,SUN Yan,et al.Study of the effect of radiation damage on different kinds of cells transfected with HRAD17[J].Chinese Journal of Radiological Medicine and Protection,2006,26(1):3-5
Study of the effect of radiation damage on different kinds of cells transfected with HRAD17
Received:September 28, 2005  
DOI:
KeyWords:HRAD17  Radiation damage  Cell cycle  Apoptosis
FundProject:国家自然科学基金资助项目(30470976)
Author NameAffiliationE-mail
QIAN Xin The Central Laboratory,Third Hospital of Beijing University,Beijing 100083,China yingbaozhu@medmail.com.cn 
HAN Yun The Central Laboratory,Third Hospital of Beijing University,Beijing 100083,China  
SUN Yan The Central Laboratory,Third Hospital of Beijing University,Beijing 100083,China  
杨业鹏 基础医学院放射医学教研室  
朱应葆 The Central Laboratory,Third Hospital of Beijing University,Beijing 100083,China  
Hits: 3694
Download times: 2420
Abstract::
      Objective To study the role of HRAD17 in DNA damage and apoptosis induced by ionizing radiation. Methods Plasmids including pDOR-neo vector,pDORHRAD17s(sense) and pDOR-HRAD17a(anti-sense) were transfected into mouse fibroblasts(NIH3T3) and human uterine cervix cancer cells(HeLa).Positive clones were screened by G418.After 48 h of serume-free culture,all kinds of transfected cells were exposed to 10 Gy γ-rays(at 2.54 Gy/min) and immediately cultured with serum.The cells were isolated and fixed by 70% ethanol,with were collected at 0,6,12,24,36 and 48 h post-irradiation,and stained by propedium iodide(PI) in the dark.Flow cytometry was performed to detect DNA in these cells. Results (Ionizing) radiation could induce G1/S arrest in normal cells transfected with sense HRAD17,but G2/M arrest in tumour cells.Interestingly,cells transfected with antisense HRAD17 showed an elevated apoptotic rate compared to the control group. Conclusion HRAD17 is able to function in both G1/S and G2/M arrest and inhibit apoptosis induced by radiation damage.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029709  On-line:0

v
Scan QR Code
&et=1946763CE42DED5D0BFDD9054A4CFE5DDA061418F1FD2822462D4E5067F43E7E98A2E5E3A0C3BEBD27E401C93E86926122A248E85878816F32B389760F907D993A680679F1304B711C2FFA8F4BEF9B3F00E5C374D8F3FD26DC09FC3E804D6EBF&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=37904DC365DD7266&aid=052D6D05B6D9CCF8&vid=&iid=CA4FD0336C81A37A&sid=38B194292C032A66&eid=94C357A881DFC066&fileno=20060103&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="37904DC365DD7266"; var my_aid="052D6D05B6D9CCF8";