DAI Guang-fu,JIN Yue-ying,KOU Ming-ying.An experimental study of microdistribution of 99mTc-DTPA at cellular level[J].Chinese Journal of Radiological Medicine and Protection,2005,25(4):319-321
An experimental study of microdistribution of 99mTc-DTPA at cellular level
Received:February 16, 2005  
DOI:
KeyWords:Cell level  Microautoradiography  Radiomedicament  Argent grain  99mTc-DTPA
FundProject:国家自然科学基金资助项目(10375091)
Author NameAffiliation
DAI Guang-fu Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China 
JIN Yue-ying Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China 
KOU Ming-ying Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China 
苑淑渝 Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China 
张良安 Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192, China 
Hits: 2393
Download times: 1869
Abstract::
      Objective Traditional MIRD method for dose assessment in nuclear medicine assumes that radionuclide is homogeneously distributed in organs, and the dose to cells and cell nucleus is presented by mean dose to the organ. This project will provide the basic method and data for planning diagnosis and treatment in nuclear medicine, for predicting and evaluating effect and risk of radio-pharmaceuticals, and for further research of microdosimetry at molecular level in nuclear medicine and biology. Method The article will describe the microdistribution of 99mTc-DTPA using microautoradiography and frozen sectioning technique. Results To describe the relationship between argent grain density and nuclide radioactivity a regression curve was depicted and the R value was calculated to be 0.9915. The grain density over cytoplasm was 1.78 times higher than that over nucleus in these cells. Conclusion The distribution of radiomedicament at cellular level is nonuniform.;
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9064625  On-line:0

v
Scan QR Code
&et=1178166153CA064E08E041E49E8B308949FB5B96196A7BFD7AC1C9AF4D0DF6750DF46D062D3FC3C4BA7FD909CB9632594620B30431B6807E0B25C28C4281F374803B1D0728D3923F6BB081A4A271E167B85F13F4B402160E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=2DD7160C83D0ACED&aid=7A67602F4C609A0B&vid=&iid=E158A972A605785F&sid=160561E9A96393DE&eid=4AD4BA66429F5627&fileno=20050407&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="2DD7160C83D0ACED"; var my_aid="7A67602F4C609A0B";