HU Ai_ying,WANG Qi_liang,XIA Pei_hua.Intercomparison of environmental dosimeters between China and Japan[J].Chinese Journal of Radiological Medicine and Protection,2005,25(3):273-274
Intercomparison of environmental dosimeters between China and Japan
Received:February 04, 2005  
DOI:
KeyWords:Environmental dosimeter  Intercomparison  Result
FundProject:
Author NameAffiliation
HU Ai_ying National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China 
WANG Qi_liang National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China 
XIA Pei_hua National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China 
Hits: 2632
Download times: 1909
Abstract::
      Objective For assuring accuracy and reliability of the monitoring results provided by thermoluminescence dosimetry laboratories,an intercomparison with JCAC was performed for several years so as to inspect the veracity and stability of measurement systems of thermoluminescence dosimetry. Methods The method adopted was sending TLD by post and setting up two different monitoring places and one control place for every time of intercomparison.One dosimeter containing six to ten detectors was placed in each measurement site.The dosimeters were measured by both laboratories after taking back. Results The results of intercomparison for three successive times showed that the consistency rates of these environmental dosimeters were all less than seven percent,i.e.,within the permissible error range. Conclusion The measurement systems of thermoluminescence dosimetry and monitoring methods adopted by these thermoluminescence dosimetry laboratories accord with the requirement of both national and international standards.The consistency has been kept for three times of comparisons in six years.The monitoring methods,the calibration reproducibility of measurement equipments,the selection of TLD and the processing methods fo comparison results adopted in intercomparison of environmental dosimeters with JCAC all reach the international level.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069603  On-line:0

v
Scan QR Code
&et=824BF5C5DCFB800C3A0C7F7D9BE8E59A1C04F8EBD9A0B8CFE413E7B4946050D5F89D424F351F6229C404A72AEC67F58CC4BF15F28A00068EDED2A9CB714821E5EBA0D447F21CA3B7&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=2DD7160C83D0ACED&aid=FEEE6F9268A41FF9&vid=&iid=38B194292C032A66&sid=9F8C5EF901EA1E7E&eid=6826CBE9C80ACB20&fileno=20050327&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="2DD7160C83D0ACED"; var my_aid="FEEE6F9268A41FF9";