ZHOU Yu,LUO Yi-sheng,GUO Yong.Remotel control and data processing for measurement of radiation Dose[J].Chinese Journal of Radiological Medicine and Protection,2004,24(5):469-471
Remotel control and data processing for measurement of radiation Dose
Received:October 03, 2003  
DOI:
KeyWords:Neutron  Dose  Computer  Remote control  Automatic measurement
FundProject:
Author NameAffiliation
ZHOU Yu Institute of Radiation Medicine, Beijing 100850, China 
LUO Yi-sheng Institute of Radiation Medicine, Beijing 100850, China 
GUO Yong Institute of Radiation Medicine, Beijing 100850, China 
纪刚 Institute of Radiation Medicine, Beijing 100850, China 
张文仲 防化指挥工程学院 
王兴功 Institute of Radiation Medicine, Beijing 100850, China 
张红 Institute of Radiation Medicine, Beijing 100850, China 
Hits: 2540
Download times: 1756
Abstract::
      Objective To protect the workers from the reactor radiation and to improve the accuracy and efficiency of neutron dose measurement. Methods With the application of remote control technology,a remote control and automatic measurement system for radiation dose measurement(especially for neutron dose) was set up.A Model 6517A electrometer was operated all automatically over RS-232 serial interface using SCPI commands with a computer. Results The workers could stay far from the reactor and be able to control the protable computer in site though internet or LAN and then to control the 6517A electrometer to implement the dose measurement.After the measurement,the data were transferred to the remote computer near the workers and shared by many experts at the first time through the net. Conclusion This is the first time that the remote control technology is applied in radiation dose measurement,which has so far been considered can only be performed at a near place.This new system can meet the need of neutron radiobiology researches as well as of the safety and health of the workers.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9078155  On-line:0

v
Scan QR Code
&et=01FFD5752342A22DD0F86E8AB78D7737FAABC8646BB6BEC8732E34B90643B3821DBBA457618F1ADEBDC310340A1DF6B32ADFB7D72103616C1DA9A44A9533D02D4CC8180530A62715&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=D0E58B75BFD8E51C&aid=56B5ECA7EDAE89E6&vid=&iid=94C357A881DFC066&sid=8F2250DA83AF77B8&eid=DCE57F652E4ADAFC&fileno=20040539&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="D0E58B75BFD8E51C"; var my_aid="56B5ECA7EDAE89E6";