XIA Jinsong,WU Hua,ZHAO Ming,et al.Monitoring biological responses of tumor cells after irradiation with 99mTc-MIBI[J].Chinese Journal of Radiological Medicine and Protection,2001,21(5):317-320
Monitoring biological responses of tumor cells after irradiation with 99mTc-MIBI
Received:November 10, 2000  
DOI:
KeyWords:99mTc-MIBI  Tumor cell  Irradiation  Biology effect
FundProject:
Author NameAffiliation
XIA Jinsong Department of Nuclear Medicine, Tongji Hospital, Tongji Medical University, Wuhan 430030, China 
WU Hua Department of Nuclear Medicine, Tongji Hospital, Tongji Medical University, Wuhan 430030, China 
ZHAO Ming Department of Nuclear Medicine, Tongji Hospital, Tongji Medical University, Wuhan 430030, China 
鲜于志群 Department of Nuclear Medicine, Tongji Hospital, Tongji Medical University, Wuhan 430030, China 
Hits: 3427
Download times: 2222
Abstract::
      Objective To explore the possibility of using 99mTc-MIBI to monitor biological responses of tumor cells after irradiation. Methods To observe the relation between the irradiation doses and the uptake levels of 99mTc-MIBI by tumor cells irradiated with a single dose of 5 Gy,10 Gy and 20 Gy,respectively.The uptake of 99mTc-MIBI in each dose group was determined before and at 24,48,72 hours after irradiation.Apoptosis index (AI) and plating efficiency (PE) of tumor cells were determined simultaneously.The relation between the uptake levels of 99mTc-MIBI in vivo (expressed as differential uptake ratio,DUR) and AIwas also determined. Results There was a negative correlation between uptake levels of 99mTc-MIBI and AI ( r=-093). Apositive correlation was shown between the uptake levels and PE ( r= 084).At 24 h after irradiation,DUR was inversely correlated with AI( r=0793). Conclusion It is suggested that 99m Tc-MIBI might be used as a tracer to monitor the change of viability state of tumor cells after irradiation with different doses.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11567895  On-line:0

v
Scan QR Code
&et=3CBA26923B1509142F6DC6B7829C32C6603D81B3A14B0B558AE09F9DB61AD0A702C8A06339A83ED32908DAE23C984DA4056DB982B37D945D3118897637C26E13B6D1DB2A937C8C06A92F1259950463293DE1616FED75512D395922198770FEAE&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=7EB49A3EECC0C696&vid=&iid=94C357A881DFC066&sid=E3094127AA4ABC1A&eid=CA9ED1AB4D9E3E04&fileno=20010501&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="7EB49A3EECC0C696";