LÜYumin,FU Baohua,HAN Lin.Biological dose assessment by chromosomal aberration analysis in Henan 60Co radiation source accident[J].Chinese Journal of Radiological Medicine and Protection,2001,21(3):151-155
Biological dose assessment by chromosomal aberration analysis in Henan 60Co radiation source accident
Received:February 12, 2001  
DOI:
KeyWords:Co radiation accident  Chromosomal aberrations  Biological dose assesssment
FundProject:
Author NameAffiliation
LÜYumin Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
FU Baohua Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
HAN Lin Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
赵凤玲 Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
陈玉浩 Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
姚仲甫 Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
罗陆军 Henan Institute of Occupational Medicine, Zhengzhou 450052, China 
Hits: 3072
Download times: 2040
Abstract::
      Objective Biological dose assessment was performed by chromosomal aberration analysis for seven victims exposed accidentally to 60 Co gamma-rays in Henan Province,P.R.China. Methods The individual radiation dose was estimated by the yields of dicentrics plus rings.The well-distributed exposure or non-uniform one was tested by the Poisson distribution of dic+r. Results The equivalent whole body doses for the seven victims were estimated to be 5.09 Gy(Mei),2.61 Gy(Tian),2.49 Gy(Wang),.89 Gy (Yong),0.74 Gy (Min),0.58 Gy(Yi) and 0.08 Gy(Yu) respectively on d4/d5 after the accident.These doses were very consistent with the mean doses calculated from physical measurement and conformable to the clinical diagnosis.The dic+r aberrations of “Mei” and “Wang” did not accord with Poisson distribution,whereas those of the other 5 cases did. Conclusion The analysis of chromosomal aberrations is an extremely reliable method in biological dosimetry.The radiations which “Mei” and “Wang” were exposed to were heterogeneous while they were homogeneous for the other 5 cases.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9075063  On-line:0

v
Scan QR Code
&et=CFF29A8A9F7401371BA92042BB080285FCCA8A8EAAD09CB0F3CA925F725763B4DD53656E7C04DAFAC645A9223CFA5C16B9DCA633E6D4D8877F7630C44A8A1BA379812D6EF493E623237328E3496D4FDE20B5A7E2EB5B1D6B67D61E68D81065ACC1AACA0804379AA6007D4EC8C73E0083CD1ED0B7FA563528&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=&vid=&iid=38B194292C032A66&sid=70AC2EF7F2065E09&eid=7CE3F1F20DE6B307&fileno=20010303&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="";