JIA Delin,YUAN Shuyu,DAI Guangfu.Simulating measurement and dose estimation for exposed persons in “4.26” 60 Co radiation source accident in Henan Province[J].Chinese Journal of Radiological Medicine and Protection,2001,21(3):150-152 |
Simulating measurement and dose estimation for exposed persons in “4.26” 60 Co radiation source accident in Henan Province |
Received:February 12, 2001 |
DOI: |
KeyWords:Co radiation source Radiation accident Simulating measurement Dose estimation |
FundProject: |
Author Name | Affiliation | JIA Delin | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | YUAN Shuyu | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | DAI Guangfu | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | 张钦富 | 河南省职业病防治所 | 卢国甫 | 河南省职业病防治所 | 姚仲甫 | 河南省职业病防治所 | 赵玉娟 | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | 寇明英 | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | 张承 | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China | 张良安 | Institute of Radiation Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China |
|
Hits: 3505 |
Download times: 2142 |
Abstract:: |
Objective To estimate physical doses of the six exposed persons in the “4.26” 60 Co radiation source accident of Henan Province. Methods The exposure models of the persons were established by survey and simulation.The distribution of exposure rate in radiation field was measured with LiF(Mg,Cu,P)TLD.The doses of the exposed persons “Mei”(female),“Wang”(8 years old,male) and “Tian” were measured with an anthropomorphic phantom.The doses of “Yong”,“Min”.“Yi” were estimated using the method of tissueair ratio. Results The doses of 19 organs and tissues of “Mei”,and “Wang” were presented in this paper.The average whole body doses of “Mei”,“Wang”and “Tian”are 6.1 Gy,3.4 Gy and 2.4 Gy,respectively.Their weighted stem cell doses are 5.0 Gy,2.6 Gy and 2.3 Gy, respectively.For “Yong”,“Min”and “Yi”,their average whole body doses are 1.1 Gy,0.9 Gy and 0.7 Gy,respectively.Their weighted stem cell doses are 1.1 Gy,0.9 Gy and 0.8 Gy,respectively. Conclusion The physical doses obtained in this work are consistent with the biological doses,clinical laboratory tests and symptoms.Reliable information of dosimetry is provided for the clinical diagnosis and treatment,and doseeffect study. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|