JIA Delin,YUAN Shuyu,DAI Guangfu.Simulating measurement and dose estimation for exposed persons in “4.26” 60 Co radiation source accident in Henan Province[J].Chinese Journal of Radiological Medicine and Protection,2001,21(3):150-152
Simulating measurement and dose estimation for exposed persons in “4.26” 60 Co radiation source accident in Henan Province
Received:February 12, 2001  
DOI:
KeyWords:Co radiation source Radiation accident  Simulating measurement  Dose estimation
FundProject:
Author NameAffiliation
JIA Delin Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
YUAN Shuyu Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
DAI Guangfu Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
张钦富 河南省职业病防治所 
卢国甫 河南省职业病防治所 
姚仲甫 河南省职业病防治所 
赵玉娟 Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
寇明英 Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
张承 Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
张良安 Institute of Radiation Medicine, Chinese Academy of Medical Sciences &
Peking Union Medical College, Tianjin 300192, China 
Hits: 3505
Download times: 2142
Abstract::
      Objective To estimate physical doses of the six exposed persons in the “4.26” 60 Co radiation source accident of Henan Province. Methods The exposure models of the persons were established by survey and simulation.The distribution of exposure rate in radiation field was measured with LiF(Mg,Cu,P)TLD.The doses of the exposed persons “Mei”(female),“Wang”(8 years old,male) and “Tian” were measured with an anthropomorphic phantom.The doses of “Yong”,“Min”.“Yi” were estimated using the method of tissueair ratio. Results The doses of 19 organs and tissues of “Mei”,and “Wang” were presented in this paper.The average whole body doses of “Mei”,“Wang”and “Tian”are 6.1 Gy,3.4 Gy and 2.4 Gy,respectively.Their weighted stem cell doses are 5.0 Gy,2.6 Gy and 2.3 Gy, respectively.For “Yong”,“Min”and “Yi”,their average whole body doses are 1.1 Gy,0.9 Gy and 0.7 Gy,respectively.Their weighted stem cell doses are 1.1 Gy,0.9 Gy and 0.8 Gy,respectively. Conclusion The physical doses obtained in this work are consistent with the biological doses,clinical laboratory tests and symptoms.Reliable information of dosimetry is provided for the clinical diagnosis and treatment,and doseeffect study.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9070910  On-line:0

v
Scan QR Code
&et=DCB591F1B485B6023F904A30901702EED67AC7DF63B3DB93399F83B702976017DCDDDFF34C89DFA92DEE97C58A69E2D53E2E293F74B7833E8046181240DD249BF1BCEF1694C3EE14CACFE1F703217EF992F71D15E0FC75A3448E2EF1AFE71A6C51C5D8AA9194C9D0D6168685B5CF0C43C642C8AAF31F2B77C09D886054F3B73F64BAB4760FFE5F5DDBA6FEA1B21D5DD7&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=B3C28B8F95648345&vid=&iid=38B194292C032A66&sid=2DBBF45CC176713E&eid=04445C1D2BDA24EE&fileno=20010302&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="B3C28B8F95648345";