YANG Jianzheng,LIANG Shuo,QU Yaqin.Effects of low dose mitomycin C on experimental tumor radiotherapy[J].Chinese Journal of Radiological Medicine and Protection,2001,21(2):100-102
Effects of low dose mitomycin C on experimental tumor radiotherapy
Received:July 21, 2000  
DOI:
KeyWords:Mitomycin C  Tumor radiotherapy  Adaptive response
FundProject:国家自然科学基金资助项目(39270236)
Author NameAffiliation
YANG Jianzheng The Second Clinical College, Norman Bethune University of Medical Sciences, Changchun 130021, China 
LIANG Shuo 白求恩医科大学预防医学院 
QU Yaqin The Second Clinical College, Norman Bethune University of Medical Sciences, Changchun 130021, China 
朴春姬 白求恩医科大学预防医学院 
张海英 白求恩医科大学预防医学院 
吴镇凤 The Second Clinical College, Norman Bethune University of Medical Sciences, Changchun 130021, China 
王献理 白求恩医科大学预防医学院 
Hits: 2655
Download times: 2140
Abstract::
      Objective To evaluate the possibility of low dose mitomycin C(MMC)as an adjuanct therapy for radiotherapy. Methods Change in tumor size tumor bearing mice was measured.Radioimmunoassay was used to determine immune function of mice. Results Low dose MMC’s pretreatment reduced tumor size more markedly than did radiotherapy only.The immune function in mice given with low dose MMC 12h before radiotherapy was obviously higher than that in mice subjected to radiotheraphy only(P<0.05),and was close to that in the tumor bearing mice before radiotherapy. Conclusion Low dose MMC could improve the radiotherapy effect.Pretreatment with low dose MMC could obviously improve the immune suppression state in mice caused by radiotherapy.The mechanism of its improvement of radiotherapeutic effect by low dose of MMC might be due to its enhancement of immune function and induction of adaptive response in tumor bearing mice.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9068279  On-line:0

v
Scan QR Code
&et=970261AF74811A5D673BCD6251A9EA6BC170B7F4859CE572ADAE16981D3A79C7D07F63C6123D6426A4EF26580D272D0D0E31D57B7E42597ADFB54AFBBCD6F4B39A3503C4D5B92893&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=5D88E2D8DEC15120&vid=&iid=0B39A22176CE99FB&sid=8C83C265AD318E34&eid=331211A5F5616413&fileno=20010212&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="5D88E2D8DEC15120";