WANG Yunlai,ZHANG Liangan,DAI Guangfu.Mean absorbed dose calculation at cellular level for targeted radiotherapy using Auger-electron-emitters[J].Chinese Journal of Radiological Medicine and Protection,2001,21(2):76-79
Mean absorbed dose calculation at cellular level for targeted radiotherapy using Auger-electron-emitters
Received:May 11, 2000  
DOI:
KeyWords:Targeted radiotherapy  Absorbed dose  Augerelectron  Svalue  Energy loss
FundProject:
Author NameAffiliation
WANG Yunlai Institute of Radiation Medicine, Chinese Academy of Medical Science and Beijing Union Medical College, Tianjin 300192, China 
ZHANG Liangan Institute of Radiation Medicine, Chinese Academy of Medical Science and Beijing Union Medical College, Tianjin 300192, China 
DAI Guangfu Institute of Radiation Medicine, Chinese Academy of Medical Science and Beijing Union Medical College, Tianjin 300192, China 
Hits: 2657
Download times: 1813
Abstract::
      Objective To calculate the mean absorbed doses at celluar and subcellular levels for uniformly and non-uniformly distributed Auger electron emitters. Methods The energy deposited in cell or nucleus by Auger electrons was analytically calculated using the polynomial representation of energy loss.S-values were subsequently computed for several target-source combinations.The absorbed dose and dose distribution were calculated for spherically symmetric radionuclide distributions depending linearly and exponentially on the radial position.The dose profile as a function of the source radial coordinate was also evaluated for typical cell sizes.The contributions of photon radiation to absorbed dose in cells were ignored. Results The mean absorbed dose and dose distribution depend largely on the size of target cells,the radiation spectrum and intracellular localization and distribution of radionuclides.The contribution of intranuclear radionuclides to mean absorbed dose was larger than that of extranuclear ones. Conclusion Auger electrons can produce high local energy deposition in cells because of their very low energies and extremely short ranges.Our dose calculation method is simple.The results are reliable and can be used in many fields.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9059663  On-line:0

v
Scan QR Code
&et=7405EA11B0BBCF802435D2FB35344FA64DA92B68FAB3ACA65A9C16C321A011D698EF4E9300F0478324504122B3E6068DCB6802E03B41ED4D2E6035AAF564676B768C87EF301EFF0285976EAB0687A581A5ED070941803CC4286D0CE4FBF2BF4399BE8B7A61D8F551A7281ED7CE1D9CDB&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=56BE6ACACA63434F&vid=&iid=0B39A22176CE99FB&sid=228A710F49B6CE58&eid=9C65ADEB5990B252&fileno=20010202&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="56BE6ACACA63434F";