ZHAO Shi’an,OU Xiangming,WANG Zuoling.Design of RD-98 X-ray Diagnostic Dosimeter[J].Chinese Journal of Radiological Medicine and Protection,2001,21(1):50-52
Design of RD-98 X-ray Diagnostic Dosimeter
Received:April 13, 2000  
DOI:
KeyWords:Xray  Diagnostic Dosimeter  Semiconductor  Detect
FundProject:卫生部科学基金课题资助项目(981082)
Author NameAffiliation
ZHAO Shi’an Laboratory of Industrial Hygiene, Ministry of Health, Beijing, 100088, China 
OU Xiangming Laboratory of Industrial Hygiene, Ministry of Health, Beijing, 100088, China 
WANG Zuoling Laboratory of Industrial Hygiene, Ministry of Health, Beijing, 100088, China 
岳保荣 Laboratory of Industrial Hygiene, Ministry of Health, Beijing, 100088, China 
尉可道 Laboratory of Industrial Hygiene, Ministry of Health, Beijing, 100088, China 
Hits: 2947
Download times: 1897
Abstract::
      Objective RD 98 X-ray Diagnostic Dosimeter was designed and developed with the characteristics of fast response,wide measuring range and independence of X-ray energy in order to improve the quality of imagine and reduce the radiation dose delivered to the tested persons under the diagnostic X-ray machine.It is suitable for measurements of dose,dose rate and exposure time in the conventional radiology. Method The detector of RD 98 X-ray Diagnostic Dosimeter is made of semiconductor of Si diode as a receiver to radiation signal.To meet the requirements of energy response,the detector is compensated by special filters.The realization of all the automatic functions is based on the CPU installed in the reader with special softwares. Results RD 98 X-ray Diagnostic Dosimeter is able to measure the dose ranging from 0.001 mGy to 9999 mGy,the dose rate ranging from 0.001 mGy/s to 9999 mGy/s and the exposure time ranging from 0.001 second to 9999 second.The energy response of the dosimeter from 55 keV to 150 keV is better than 5% and its reproducibility during one month is within 99%.The readings are displayed by 4 digit LED and RS-232 port is matched for the connection of a mini-printer. Conclusion The RD 98 X-ray Diagnostic Dosimeter can be used as a test tool by itself or by a suitable combination with other equipments for quality control in X-ray diagnostic field of hospitals.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9073124  On-line:0

v
Scan QR Code
&et=5FA1CBB1D71C105A647AFB87E5F1C20BC825D25F5061C1F912F7CA25399E0924426C102F19238CFDEC86AADB42F52C9A&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=14E7EF987E4155E6&aid=798CC6B8EE8BDBDA&vid=&iid=CA4FD0336C81A37A&sid=771152D1ADC1C0EB&eid=286FB2D22CF8D013&fileno=20010126&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="14E7EF987E4155E6"; var my_aid="798CC6B8EE8BDBDA";