BAI Yunhong,WANG Dewen,CUI Xuemei.Effect of ligustrazine and diltiazem on fibroblast proliferation and expression of basic fibroblast growth factor following 60Co γ ray irradiation[J].Chinese Journal of Radiological Medicine and Protection,1999,19(6):379-380
Effect of ligustrazine and diltiazem on fibroblast proliferation and expression of basic fibroblast growth factor following 60Co γ ray irradiation
Received:May 07, 1998  Revised:April 06, 1999
DOI:
KeyWords:Irradiation  Fibroblast  Fibroblast growth factor
FundProject:
Author NameAffiliation
BAI Yunhong Institute of Radiation Medicine, Beijing 100850, China 
WANG Dewen Institute of Radiation Medicine, Beijing 100850, China 
CUI Xuemei Institute of Radiation Medicine, Beijing 100850, China 
宋良文 Institute of Radiation Medicine, Beijing 100850, China 
夏国伟 Institute of Radiation Medicine, Beijing 100850, China 
刘玉福 北京同仁医院眼科 
Hits: 2482
Download times: 1510
Abstract::
      Objective In order to provide experimental basis for drug research of preventing and treating radiation pulmonary fibrosis,the authors observed the effect of ligustrazine and diltiazem on fibroblast proliferation and expression of basic fibroblast growth factor (bFGF) following 60 Co γ ray irradiation. Methods NIH/3T3 fibroblast proliferation and expression of bFGF were observed respectively by using MTT[3-(4,5-dimethylthiazo(-2-zyl) 2,5-diphenyl tetrazolium bromide)] method and ABC immunocytochemistry staining. Results The optical densities of bFGF were 0.71+0.22 for control group, 1.03+0.21 for irradiation group (Ⅰ), 0.47+0.15 for ligustrazine+irradiation group,1.05+0.21 for irradiation group (Ⅱ),and 2.02+0.21 for diltiazem+irradiation group.The mean optical densities of bFGF were 0.028+0.005,0.044+0.006,0.029+0.001,and 0.0036+0.003 for control group,irradiation group,ligustrazine+irradiation group,and diltiazem+irradiation group, respectvely. Conclusion Ligustrazine can inhibit the NIH/3T3 fibroblast proliferation and expression of bFGF,but diltiazem does not show such an effect.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066399  On-line:0

v
Scan QR Code
&et=FF4EC6B96077DFE779E561D9F53699F84E3750AD1275714EB2C34F13FB3968116597C5722A691A515FAD250C6FE6C4E8C9D0A30493857F2AA8B7DF4C114813AE72F440354AB2151EFABC2AE12871004EDE80D75B167977ECB8EA93BD643B42C3921F12BC2546BD77798A6E92F6DEABCE796BF44D435E8FF1031E29B546D0553300B74D73E65C307DFB323052399D36814ACD4C5ABABE17C1882687E9B92C03DE&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B914830F5B1D1078&aid=A75147E6EF794A0A097ED07DACAC75F1&vid=&iid=B31275AF3241DB2D&sid=9EF602EA28138BEA&eid=A7AE820C12CC9AD3&fileno=19990605&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B914830F5B1D1078"; var my_aid="A75147E6EF794A0A097ED07DACAC75F1";