Mutations at HPRT loci and micronuclei induced by late fission products in peripheral blood lymphocytes of rats
Received:August 12, 1998  Revised:November 17, 1998
DOI:
KeyWords:Late fission products  HPRT gene mutation  Micronucleus  Dose effects  Doserate effects
FundProject:
Author NameAffiliation
XU Yongzhong Faculty of Radiation Medicine, Suzhou Medical College, Suzhou 215007, China 
ZHAO Jingyong Faculty of Radiation Medicine, Suzhou Medical College, Suzhou 215007, China 
LAO Qinhua Faculty of Radiation Medicine, Suzhou Medical College, Suzhou 215007, China 
Hits: 2849
Download times: 1778
Abstract::
      Objective The probability of mutations at HPRT loci used as a biological dosimeter was studied. Methods With the technique of multinuclear cell and cytokinesis-block micronucleus (CBMN) method, the relationships between mutations at HPRT loci, micronucleus and accmulative doses and dose-rates were studied. Results On the first day after intravenous injection of late fission products(accumulative dose 1.73cSv), by comparison with the control group, the HPRT variant frequencies, micronucleate cell frequencies and micronucleus frequencies increased significantly( P <0.01).There existed relationships between variant frequencies at HPRT locus, micronuclear cell frequencies, micronucleus frequencies and accumulative doses, which could be described by the following regression equation:Y=a+blnX, respectively.At the same accumulative dose, both the relationships between HPRT variant frequencies, micronucleus frequencies and dose-rates could be expressed by the logarithmic regression equation:Y=a+blnX.A good linear relationship between HPRT variant frequencies and micronucleus frequencies was observed. Conclusion HPRT gene locus is an endpoint very sensitive to injurious effects resulting from late fission products and has a good dose-response relationship.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9070095  On-line:0

v
Scan QR Code
&et=197F48E30F01B0159178E79E1FCF613F5133DB3196CBE04801A4F59E19BBB34FEB1C76BB67796B02BBE9D77A2D4F23C6B204BC8296582FA411F5450C3C6F40E38ADA8D17EAF3F7D2F86AB8B09DA14AD2D14FB1F2FC60FACF476794915EF817DB2B81422B2BD29228634C3EF06A4C0927&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B914830F5B1D1078&aid=C9FEDCB7AAF92C44DA76656E23BFED6A&vid=&iid=94C357A881DFC066&sid=5FF9F4F7CB1800C7&eid=9D9F10A828991FA6&fileno=19990517&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B914830F5B1D1078"; var my_aid="C9FEDCB7AAF92C44DA76656E23BFED6A";