ZHOU Ying,QU Wanying,YAO Zhiming.Experimental study of hypoxia imaging agent 99m Tc-HL91 in mice bearing glioblastoma G422[J].Chinese Journal of Radiological Medicine and Protection,1999,19(3):198-200
Experimental study of hypoxia imaging agent 99m Tc-HL91 in mice bearing glioblastoma G422
Received:March 01, 1999  Revised:April 26, 1999
DOI:
KeyWords:Technetium-HL91  Mice  Glioblastoma
FundProject:国家攀登计划B项目资助
Author NameAffiliation
ZHOU Ying 100730 北京, 北京医院核医学科 
QU Wanying 100730 北京, 北京医院核医学科 
YAO Zhiming 100730 北京, 北京医院核医学科 
陈方 北京协和医院核医学科 
朱明 100730 北京, 北京医院核医学科 
朱霖 国家标准物质研究中心 
Hits: 2791
Download times: 1707
Abstract::
      Objective To evaluate the ability of detecting cerebral tumor by 99m Tc-HL91 in mice bearing glioblastoma G422. Methods Six model mice underwent static whole body planar imagings at once and at 1,2,3,4,6,7,8h postinjection of 99m Tc-HL91.Three mice each were killed at 4h and 8h,respectively.The tumor,blood and organs were removed,weighted and the radioactivity was measured.ROIs were drawn around tumor,head,contralateral axilla and chest in whole body planar images,and the radioactivity ratios of tumor to head (T/H),contralateral axilla (T/A) and chest (T/C) were calculated. Results Increased tumor activity was indentified in static whole body planar images since 1h postinjection.At 2h postinjection,T/H,T/A and T/C were 2.93±0.51,4.86±0.79 and 2.00±0.35 respectively,which were significantly higher than those at once and at 1h postinjection ( P <0.05, P <0.01).The radioactivity ratios in per unit weight of tumor to blood,muscles,brain,heart and lungs at 4h postinjection were much higher than those of tumor to liver,spleen,stomach,intestines and kidneys. Conclusion Retention ratio of 99m Tc-HL91 in tumor tissue of mice bearing glioblastoma G422 is increased and clearance rate is decreased. 99m Tc-HL91 imaging is suitable for gliblastoma at 2h postinjection.It is appropriate to image tumors in head,neck,thorax,bone and soft tissues,but not in abdominal area.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9059833  On-line:0

v
Scan QR Code
&et=3B5D9771435A916B26445566CEFC6D4B35970C68A0BE0856F1232E88C727B1780EF36D4287824F4BCDC821D7F0A3B19086D4B212AB72E3CA1CF2A9EDFE1EB1874E005C83D824CAA1E53A3415FF713272B50D6FE4B03A896CD8BE9ECD3D4D5B460A38E26E5C2805BD&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B914830F5B1D1078&aid=5214D3D3DFA9FFE4B7DDA9FD15F419AE&vid=&iid=38B194292C032A66&sid=FEF02B4635FE8227&eid=1E41DF9426604740&fileno=19990326&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B914830F5B1D1078"; var my_aid="5214D3D3DFA9FFE4B7DDA9FD15F419AE";