Li Xiaxin,Hong Ping,Cheng Shaojie,et al.Change of telomerase activity in gamma irradiated hematopoietic cells.[J].Chinese Journal of Radiological Medicine and Protection,1998,18(6):377-380
Change of telomerase activity in gamma irradiated hematopoietic cells.
Received:April 03, 1997  Revised:November 24, 1997
DOI:
KeyWords:Gamma rays  Hematopoietic cells  Telomerase  Cell cycle
FundProject:军队“八·五”青年基金
Author NameAffiliation
Li Xiaxin Nanfang Hospital, The First Military Medical University, Guangzhou 510515, China 
Hong Ping 广州军区第一五七医院儿科 
Cheng Shaojie Nanfang Hospital, The First Military Medical University, Guangzhou 510515, China 
F.Leteurtre 法国巴黎圣-路易医院血研所 
Hits: 4506
Download times: 2810
Abstract::
      Objective Using two hematopoietic cell lines, KGla and CEM, to investigate the variation of telomerase activity after γ-irradiation.Methods After irradiation, cell proliferation was measured by thymidine incorporation and telomerase activity of cells was analysed by Kim's TRAP assay. Cell synchronization was achieved after two-step thymidine blocks, and cell cycle was examined by BrdU incorporation technique for verifying cell cycle distribution after irradiation and cell synchronization.Results Telomerase activity increased after irradiation of between 0 and 3Gy in a dose-dependent manner, reaching the maximum at 3 Gy. The increase of telomerase activity was nearly to its maximum 8h after irradiation, the peak being observed at around 24h. Although this kinetics partly correlated with cell redistribution into the G2/M phase of the cell cycle, telomerase activity did not show significant variation over the cell cycle.Conclusion The up-regulation of telomerase in hematopoietic cell lines after γ-irradiation may suggest the involvement of telomerase in DNA repair and chromosome healing.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12034795  On-line:0

v
Scan QR Code
&et=084C6989E68AAF71930C9E00C8A56D751B382DA36D1581095A3A3BAE501F020B8CFB7C5F4ED4D58A73DF8944D310A989FCB737172CC1D62EF0494653D39CF192DDDBD81BE159676E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8CAA3A429E3EA654&aid=F531442B09EE4CB7&vid=&iid=B31275AF3241DB2D&sid=389106FB36CA8332&eid=A7AE820C12CC9AD3&fileno=19980604&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8CAA3A429E3EA654"; var my_aid="F531442B09EE4CB7";