,et al.Morphometric changes in epithelial cell nuclei of rat thyroid follicles induced by 131I and 132I[J].Chinese Journal of Radiological Medicine and Protection,1998,18(4):266-269
Morphometric changes in epithelial cell nuclei of rat thyroid follicles induced by 131I and 132I
Received:December 03, 1997  Revised:February 27, 1998
DOI:
KeyWords:
FundProject:
Author NameAffiliation
曹珍山 100850 北京, 北京放射医学研究所 
樊飞跃 100850 北京, 北京放射医学研究所 
涂开成 100850 北京, 北京放射医学研究所 
谢国良 100850 北京, 北京放射医学研究所 
杨素霞 100850 北京, 北京放射医学研究所 
李煜 100850 北京, 北京放射医学研究所 
刘国廉 100850 北京, 北京放射医学研究所 
叶常青 100850 北京, 北京放射医学研究所 
Hits: 3174
Download times: 1272
Abstract::
      Objective To study harmfulness of radioiodine and its medical protection.Method By using image analysis technique and morphometry, changes in morphometric parameters in epithelial cell nuclei of rat thyroid follicles were determined 20 months after injection of 131I and 132I.Results The results showed that in various dosage groups the area and eqivalent diameter enlarged, the morphometric factor was evidently smaller than that of the control group(P<0.05 or P<0.01), and the form irregular index was significantly larger than that of the control group (P<0.05 P<0.01).The volume density, surface area density, numerical density of nuclei of follicular epithelial cells in various dose groups all showed the feature of increase at first and reduction afterwards.Conclusion It is indicated that the nuclei of epithelial cells increased and its shape became not only flat, but also anisomorphic after the cells were irradiated with radioiodine.The reason why volume density and surface area density showed increase or decrease is due to the change in numerical density of nuclei of epithelial cells.It was found by regresion analysis of the numerical density of nuclei of epithelial cells and incidence of thyroid tumor induced by radioiodine that they bear a remarkable positive correlation[Y=1/(3.37×103 +5.85×103/X1), R1=0.8435], suggesting that the incidence of thyroid tumor is related to the number of cell per unit volume.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11567836  On-line:0

v
Scan QR Code
&et=6B508A615565CB5899736C8EAB512429D79409DAAE995A7A42492DD3F0EC8C7EB1B013DD92CFD1BD56505CBF9E7222F432F85AA7CA57E0A8573175050924E3CBB3367BED725EF93CFC3D2731675CAD094DB1C4D4EA44A1A100FC48D95AB68D29857AAE1231FC3E776DD2058703CD5AD2E5C180CDDACC115C&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8CAA3A429E3EA654&aid=5B22CF8F6AC8E81E5A7AACA2EE2CA26C&vid=&iid=E158A972A605785F&sid=4FE459D71E3BF8EB&eid=1A363081E1FF7014&fileno=19980421&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8CAA3A429E3EA654"; var my_aid="5B22CF8F6AC8E81E5A7AACA2EE2CA26C";