Tian Qiong,Zhang Shaozhang,Pu Qin,et al.Effect and mechanism of rhBMP-2m on acute hemopoietic radiation injury in mice[J].Chinese Journal of Radiological Medicine and Protection,1998,18(4):253-255
Effect and mechanism of rhBMP-2m on acute hemopoietic radiation injury in mice
Received:November 05, 1997  Revised:March 03, 1998
DOI:
KeyWords:rhBMP-2m  Acute radiation injury  Bone marrow form  CFU-GM
FundProject:
Author NameAffiliation
Tian Qiong 710032 西安, 第四军医大学放射医学教研室 
Zhang Shaozhang 710032 西安, 第四军医大学放射医学教研室 
Pu Qin 生物化学教研室 
张发科 710032 西安, 第四军医大学放射医学教研室 
任东青 710032 西安, 第四军医大学放射医学教研室 
陈苏民 生物化学教研室 
Hits: 3818
Download times: 1491
Abstract::
      Objective To study the effect of rhBMP-2m on irradiated mice.Method 104 male BALB/c mice were randomized to several groups and exposed to 6.5-7.5 Gy whole body 60Co γ rays.After irradiation a dose from 0.5 to 2.0 mg rhBMP-2m in saline were injected i.p. once daily in 1 6 consecutive days, and the animals' 30 day survival was scored.Some indices with relation to hematogenesis were observed as well at ninth day after irradiation.Results It was showed that the 30 day survival, mean survival time, count of bone marrow cells, DNA content of bone marrow cells, count of CFU-GM on agar culture, peripheral blood WBC count, spleen/body weight ratio and number of spleen colony formation were all significantly higher in 2.0 mg rhBMP-2m treated groups than those in the corresponding irradiated controls (P<0.01).Conclusion The beneficial effect of rhBMP-2m on the hemaotogenesis in irradiated mice can be ascribed supposedly to that the rhBMP-2m may induce the release of hematopoietic growth factor(s) in irradiated animal body, or it may act as a hematopoietic growth factor itself, or it may induce a hematopoietic microenvironment to support the growth of stem cells.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12032874  On-line:0

v
Scan QR Code
&et=A0058C3448EF466947CC11C8B8C9B1869B37DE16DE11CB10AD4B7CEA274A44351D776CD50D80D6B7A3783D4ED885A8CAE58FCCD5C22C982C3B8595E32E8F870A5C509BBF68A8E840F9F8ED352507F0A1&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8CAA3A429E3EA654&aid=D2CEDB5F6A85B4D0&vid=&iid=E158A972A605785F&sid=82722E2B785EBF0D&eid=627456E7977439A4&fileno=19980414&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8CAA3A429E3EA654"; var my_aid="D2CEDB5F6A85B4D0";