Li Mei ying,Zhang Yaozhen,Zhang Donghua,et al.Clinical report of four cases of acute radiation sickness in a 60Co radiation accident in Wuhan[J].Chinese Journal of Radiological Medicine and Protection,1998,18(4):230-234
Clinical report of four cases of acute radiation sickness in a 60Co radiation accident in Wuhan
Received:October 17, 1997  Revised:February 20, 1998
DOI:
KeyWords:Bone marrow form acute radiation sickness  Radiation dose  Cobalt-60γ-rays  Radiation accident
FundProject:
Author NameAffiliation
Li Mei ying 430030 武汉, 同济医科大学附属同济医院 
Zhang Yaozhen 430030 武汉, 同济医科大学附属同济医院 
Zhang Donghua 430030 武汉, 同济医科大学附属同济医院 
鲜于志群 430030 武汉, 同济医科大学附属同济医院 
汪道文 430030 武汉, 同济医科大学附属同济医院 
张良华 430030 武汉, 同济医科大学附属同济医院 
肖昶明 430030 武汉, 同济医科大学附属同济医院 
侯祖洪 湖北省放射卫生防护所 
姜恩海 中国医学科学院放射医学研究所 
Hits: 4100
Download times: 1646
Abstract::
      Objective To sum up clinical experience from assessment of radiation dose, clinical course, diagnosis and treatment of four cases of acute radiation sickness (ARS) in a 60Co radiation accident on 13 November, 1992, in Wuhan, China.Methods Radiation doses were assessed by simulation test of accident site, thermoluminescent dosimetry of ruby, and analysis of chromosome aberration and micronuclear rates in peripheral blood.Diagnosis was based on analysis of irradiation doses, clinical manifestations and laboratory results.In therapeutical aspect, GM-CSF was administered on the basis of comprehensive treatment.Results Four cases of ARS, including 1 case of moderate degree on the severe side, 1 case of moderate degree and 1 case of mild degree bone marrow form, as well as 1 case of overexposure, were meticulously treated for 62 to 68 days. The patients' conditions took favourable turn. The therapeutic effects were good. Conclusion From the clinical point of view we stress that (1) as soon as it is possible to estimate the degree of severity of ARS accurate diagnosis should be made;(2) early comprehensive treatment should be given according to the therapeutic principles of National Standard GB8280-87;(3)to improve the curative effect, GM-CSF should be given at the right time.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12032480  On-line:0

v
Scan QR Code
&et=3C06DB566315F8DCECCD04F59F6589D3D6DD2F36AA8D9B1473E560F874D194D8844E571637B6D832581720271AC065BD0E1F8A992E906DE05C5C103B698EA1AA48985718ECAF44359DF03B573944B70CE8A525E67244623751EBB7A6F42E0252A7692590CEA608DFED64ACB8F0F4AC54&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8CAA3A429E3EA654&aid=A8A238C41D843CEC&vid=&iid=E158A972A605785F&sid=D6354F61445E9456&eid=D9AE183D3F5C3C75&fileno=19980404&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8CAA3A429E3EA654"; var my_aid="A8A238C41D843CEC";