Su Xu,Wan Hong,Liu Shuzheng.Effect of low dose radiation on expression of apoptosis related gene products[J].Chinese Journal of Radiological Medicine and Protection,1998,18(2):77-79
Effect of low dose radiation on expression of apoptosis related gene products
Received:June 04, 1996  Revised:October 03, 1996
DOI:
KeyWords:Apoptosis  Thymocytes  Low dose radiation  p53  bcl-2  bax proteins
FundProject:国家自然科学基金
Author NameAffiliation
Su Xu MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun 130021, China 
Wan Hong MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun 130021, China 
Liu Shuzheng MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun 130021, China 
Hits: 2608
Download times: 1483
Abstract::
      Objective To study the expression of p53,bcl-2 and bax proteins in thymocytes following low dose radiation (LDR) and to explore the molecular mechanism of radiation hormesis and dose effect “J” shape curve of apoptosis induced by radiation.Methods Kunming mice were subjected to whole body irradiation (WBI) with 75 mGy X-rays.The expression of p53,bcl-2 and bax proteins was analyzed by flow cytometry 24 hours after irradiation.Results It was found that the expression of p53 protein significantly decreased (P <0.005).The expression of bcl-2 protein showed slight but not significant increase,while expression of bax protein showed slight but not significant decrease.However,the ratio of bcl-2/bax was significantly increased (P <0.05).Conclusion The changes in expression of p53 and bcl-2/bax ratio after WBI with LDR indicate that p53 and bcl-2/bax play an important role in genic regulation on apoptosis induced by radiation.The results may provide significant data for elucidating the molecular mechanism of radiation hormesis and dose effect “J” shape curve of apoptosis induced by radiation.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9058399  On-line:0

v
Scan QR Code
&et=FF4EC6B96077DFE7EF721139039AFF6AE64F69775C8A6B21F70ABD2A3E2B0DCB38FCB409881CD6D6580A7725ECA62FC9933E729ACC4D1ADE5B280E3DB90B9EC23B7D77FFFCC38D89759E9FD7F101F2AA&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8CAA3A429E3EA654&aid=893FDE4BC8285FA2&vid=&iid=0B39A22176CE99FB&sid=E44E40A2398D4F2A&eid=9C65ADEB5990B252&fileno=19980202&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8CAA3A429E3EA654"; var my_aid="893FDE4BC8285FA2";