Jiang Tao,Wang Chunyan,Chen Deqing,et al.Quantitative study of unstable chromosome aberrations following life time exposure of high background radiation in China[J].Chinese Journal of Radiological Medicine and Protection,1997,17(6):390-394
Quantitative study of unstable chromosome aberrations following life time exposure of high background radiation in China
Received:June 05, 1997  Revised:September 25, 1997
DOI:
KeyWords:High background ionizing radiation  Family member  Chromosome aberrations  Quantitative analysis
FundProject:
Author NameAffiliation
Jiang Tao Laboratory of Industrial Hygiene, Ministry of Health Beijing 100088, China 
Wang Chunyan Laboratory of Industrial Hygiene, Ministry of Health Beijing 100088, China 
Chen Deqing Laboratory of Industrial Hygiene, Ministry of Health Beijing 100088, China 
Yuan Yongling 湖南省劳动卫生职业病防治研究所 
魏履新 Laboratory of Industrial Hygiene, Ministry of Health Beijing 100088, China 
早田勇 千叶放射线医学综合研究所 
森岛弥重 近畿大学 
中井斌 京都体质研究会 
菅原努 京都体质研究会 
Hits: 3258
Download times: 1944
Abstract::
      Objective To obtain a quantitative data regarding high background radiation induced human chromosome aberrations by using advanced techniques.Methods Environmental exposure dose for each individual was carefully measured.The estimated life time doses ranged 25.2-244.8 and 5.4-51.7mGy for individuals from the high background radiation area (HBRA) and the control area,respectively.Peripheral blood specimens were taken from 28 family members of three different generations in both areas.Purified lymphocyte culture technique for chromosome preparation was adopted and a total number of 70000 metaphases were scored.Results In the case of HBRA,the frequencies of Dic+Rc increased with age,but no age dependency was observed in subjects from the control area.The mean aberration yields significantly in excess of control value were seen in two older age groups.The aberration frequencies increased in proportion to the cumulative dose of the individuals living in HBRA.The estimated rate of increase per mGy was 1.5×10-5 per cell.Conclusion It seems that Dic can continuously accumulated over life time chronic low dose exposure and can serve as a reliable biological indicator.When the dose reduces to about 50mGy, however,it becomes difficult to use the current method for quantitative analysis.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11567895  On-line:0

v
Scan QR Code
&et=475F114B57537C4901D7D358E8831C198399B296E5B06EE41E256966D975BFD893736DB5EA9B48A04B773EDDF753050E8946B72398BA6463839D731E85927492A3AA41A08B8607B6853C224629A7049B5979C9CF0E77B415F7015B5E0804A80771C3E1C3A7369EE711DE0F1BBC4EB447402506840DFAC046831FCA364C98C515&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=5370399DC954B911&aid=1AB9FA196D133A13F39CCF1F12305384&vid=&iid=B31275AF3241DB2D&sid=A22854835F81B3F8&eid=0BD4FAD4A90498AB&fileno=19970605&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="5370399DC954B911"; var my_aid="1AB9FA196D133A13F39CCF1F12305384";