Jing Aoxing,Wang Siying,Wei Daoyan.Mechanism of low level ionizing radiation in inhibiting B16 melanoma blood borne pulmonary metastasis[J].Chinese Journal of Radiological Medicine and Protection,1997,17(4):236-238
Mechanism of low level ionizing radiation in inhibiting B16 melanoma blood borne pulmonary metastasis
Received:December 19, 1996  Revised:April 17, 1997
DOI:
KeyWords:Low level ionizing radiation  B16-melanoma cells  Clearance  Immune function
FundProject:国家自然科学基金
Author NameAffiliation
Jing Aoxing Department of Nuclear Medicne, Anhui Medical University, Hefei 230032, China 
Wang Siying 肿瘤研究室 
Wei Daoyan Department of Nuclear Medicne, Anhui Medical University, Hefei 230032, China 
黄帼 Department of Nuclear Medicne, Anhui Medical University, Hefei 230032, China 
Hits: 2714
Download times: 1685
Abstract::
      bjective To study the mechanism of low level ionizing radiation in inhibiting B16 melanoma blood borne pulmonary metastasis. Method 125I labelled B16 melanoma cells were used to investigate the effect of low dose X irradiation on the distribution and clearance of tumor cells in mice. Results After whole body 7.5 cGy X-irradiation,the clearance of tumor cells was siginificantly increased from lungs of mice.The residual numbers of tumor cells were markedly lower than those of control in blood,spleen,liver and lungs (P<0.05-0.01).The cytotoxicity of murine splenic NK cells,LTR and the phagocytosis of macrophages augmented significantly after the mice were irradiated with low dose X-rays. Conclusion These results suggest that the enhancement of NK cytotoxicity and macrophage phagocytotic function might be one of the important reasons why low dose radiation can accelerate the clearance of tumor cells from the lungs.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9056683  On-line:0

v
Scan QR Code
&et=E22CCAC3ED7D530657F0D2B9127ADE62E428AAFDC5B4BDBBE1A7CD594E208A3E3109E62EEE5B6A8BD279E27FA6FC7F71CDE184A8DB4CCC0E6B85A3248991C505E7CB0A983FB6B32CC1308A101EC17BCB3E33228EA4E9033168D6E6CFA4464B8F5ECC613EBC69F0FA17A39469BA41622F9D3427FC9ABFC572&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=5370399DC954B911&aid=43B1C4D406DE3C34AAFEF140FFE92F40&vid=&iid=E158A972A605785F&sid=FBCA02DBD05BD4EA&eid=9CA95D22FC1D537C&fileno=19970405&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="5370399DC954B911"; var my_aid="43B1C4D406DE3C34AAFEF140FFE92F40";