Yang Zhaohua,Sun Meizhen,Ni Zhenli,et al.Synthesis of bimolecule substituted phenols and their effect on rats for removal of radiothorium[J].Chinese Journal of Radiological Medicine and Protection,1997,17(3):178-181
Synthesis of bimolecule substituted phenols and their effect on rats for removal of radiothorium
Received:December 16, 1996  Revised:January 25, 1997
DOI:
KeyWords:Chelating agents  Thorium-234  Decorporation drug
FundProject:国家自然科学基金
Author NameAffiliation
Yang Zhaohua China Institute for Radiation Protection, Taiyuan 030006, China 
Sun Meizhen China Institute for Radiation Protection, Taiyuan 030006, China 
Ni Zhenli China Institute for Radiation Protection, Taiyuan 030006, China 
陈桂宝 China Institute for Radiation Protection, Taiyuan 030006, China 
罗梅初 China Institute for Radiation Protection, Taiyuan 030006, China 
Hits: 5048
Download times: 2374
Abstract::
      Objectives To search for new therapeutic chelating agents for removal of incorporated radiothorium. Methods New chelating agents (bimolecule-substituted phenols) were synthesized through Mannich reaction.These compounds were administered i.m.to SD rats after i.v.injection of 234Th .Two days later the radiothorium was assayed and the excretion and retention rates were calculated.Results These chelating agents could increase the excretion of 234Th in urine and feces and decrease its retention in liver and skeleton of rats.Among them No.Ⅷ is the best one, which could promote excretion of 68%. 234Th after two days and the retention of 234Th deposited in the tissues (liver and skeleton) was only 11.7%, as compared with 87.6% in the control group. Conclusions The chelating agent No.Ⅷ is worth further investigation.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:17878226  On-line:0

v
Scan QR Code
&et=D765CBF69663A2CA2F0003D3566F0AD9007BAC469021B64C40A4E48BB2854DD0EA9F45203C3EB1DBB567CC236D110C6981E9AE44C2F2D24922D39809C67AC01DB6574A5733E91CF6BBB0AE8B398091D4B440BD96430CA98A24DE8077D63A26FAB61F701F61F7DF6C&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=5370399DC954B911&aid=4507AF543EE86E22BD62E36A0A8D2B82&vid=&iid=38B194292C032A66&sid=4609832E4B5C797B&eid=7EBE588F611589FC&fileno=19970314&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="5370399DC954B911"; var my_aid="4507AF543EE86E22BD62E36A0A8D2B82";