Wu Ke,Cong Jianbo,Wang Shu.Research and application of ESR dosimetry for dose assessment in nuclear accidents[J].Chinese Journal of Radiological Medicine and Protection,1997,17(3):159-161 |
Research and application of ESR dosimetry for dose assessment in nuclear accidents |
Received:November 29, 1996 Revised:December 15, 1996 |
DOI: |
KeyWords:ESR Radiation accident Dosimetry |
FundProject: |
Author Name | Affiliation | Wu Ke | Institute of Radiation Medicine, Beijing 100850, China | Cong Jianbo | Institute of Radiation Medicine, Beijing 100850, China | Wang Shu | Institute of Radiation Medicine, Beijing 100850, China | 孙存普 | Institute of Radiation Medicine, Beijing 100850, China | 史元明 | Institute of Radiation Medicine, Beijing 100850, China |
|
Hits: 2510 |
Download times: 1455 |
Abstract:: |
Objective This work was intended to establish methods suitable to practical dose detection for people involved in ionizing radiation accident. Methods Some biological materials of human body and articles possibly carried or worn by victims were taken as detection samples.By using electron spin resonance (ESR) techniques, the basic dosimetric properties of selected materials were investigated in the range above the threshold dose of human acute hemopoietic radiation syndrome.The involved dosimetric properties included dose response properties of ESR signals, signal stabilities, distribution of background signals, the lowest detectable dose value, radiation conditions, environmental effects on detection process etc. Results Several practical dose analytical indexes and detecting methods were set up.Some of them were successfully used in the dose assessment to people involved in three actual radiation accidents including the Chernobyl reactor accident. Conclusions This work further proves the important role of ESR played in dose estimation in radiation accident. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|