Fu Haiqing,Li Xiuyi,Li Youjun.Whole-body low dose irradiation suppresses cancer cell dissemination in mice[J].Chinese Journal of Radiological Medicine and Protection,1996,16(5):307-309
Whole-body low dose irradiation suppresses cancer cell dissemination in mice
Received:October 01, 1995  Revised:February 13, 1996
DOI:
KeyWords:Low dose radiation  Cancer cells  NK cells  IL-2 secretion
FundProject:国家自然科学基金
Author NameAffiliation
Fu Haiqing MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun, 130021 
Li Xiuyi MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun, 130021 
Li Youjun MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun, 130021 
刘树铮 MH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, Changchun, 130021 
Hits: 2545
Download times: 1321
Abstract::
      Lewis lung carcinoma or B16melanoma cells were injected into the retrobulbar vein of mice 24h after whole-body irradiation (WBI) with 50, 75 , 100 or 150 mGy X-rays.The dissemination of the cancer cells as evaluated by counting the tumor nodules on the lung surface 14d after injection was found to be markedly decreased in the irradiated rnice as compared with the sham-irradiated control.In mice given 75 mGy WBI 24h before injection of Lewis lung carcinoma cells the splenic NK cell activity and IL-2 secretion were found to be potentiated 2-6 days after irradiation in comparison with the sham-irradiated mice which received the same number of tumor cells.The results suggest that low dose radiation might suppress cancer cell dissemination via the enhancement of immune rcactivity.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9070293  On-line:0

v
Scan QR Code
&et=6EDD6AA32900DB657DA2527E06AB8766E8F117176C8F255BDCC2E027BF95E67E39C848901E16AE73614FA300E15847C66CE7DDE5ADEC7285A85A260A0D6A9AB6CC08C9F69B775D9C7EAD315F0A84C262&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=2CE72A2C6644564AD1D81C89C7C4527F&vid=&iid=94C357A881DFC066&sid=F416A9924F23B020&eid=F637763636425CAF&fileno=19960506&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="2CE72A2C6644564AD1D81C89C7C4527F";