Yang Boyun,Zhu Jianwen,Zhu Yongkang,et al.Evaluation of level of personaol external exposure dose to radiation staffs in Shanghai during 1990-1994[J].Chinese Journal of Radiological Medicine and Protection,1996,16(4):264-267
Evaluation of level of personaol external exposure dose to radiation staffs in Shanghai during 1990-1994
Received:October 05, 1995  Revised:February 18, 1996
DOI:
KeyWords:Individual dose equivalent
FundProject:
Author NameAffiliation
Yang Boyun Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
Zhu Jianwen Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
Zhu Yongkang Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
Shen Jinfu Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
Chen Lifang Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
沈跃芳 Shanghai Sanitary-Epidemiologicalstation, shanghai, 200335 
Hits: 3113
Download times: 1690
Abstract::
      Anew method used for estimating several parameters of personal dose monitoring of radiation staffs,which were recommended by the UNSCEAR in 1982(the individual annual average dose equivalent,the annual collective dose equivalent and the ratio of the annual collective dose eqaivalent delivered at individual dose exceeding 15 mGy per year to the total annual collective dose),MR15 was proposed and has been employed to evaluate the level of the personal external exposure dose to radiation staff in Shanghai.The annual average dose equivalent for radiation workers was 0.40-0.404mSv,which was less than 1/10 of the national criterion(5mSv);however,the person-times exposed to more than 3/10 of the criterion were 116,MR15 being 0.01-0.49.328 person-times surpassed the investigation level(the limit value of the monthly dose is 1.20mSv).Those people were specially paid visits and“true”or“false”was identified in detail.Moreover,both personal protective measures and other aspects to be improved were suggested.The key points of the improvement in personal protection and of personal dose monitoring were commented.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12031897  On-line:0

v
Scan QR Code
&et=D700F206953109B329AC39B376109A4E539DAE90BCD7037D1A24FDDD8EF095936C3B9BFBDF431AF405D290232C99A5C597D85FB47A35911EAEDB28F4C0CB030702CB451BE82A7DA44D2DE0360A71DFD76858B273C74BF79A0063570C21E0490C02B292CE213FED8CA640EF4FC2E947B4&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=57D61963715D0FE37F0B5928655DE7D2&vid=&iid=E158A972A605785F&sid=7ABC4505E3960D2B&eid=866F8A6B640835A7&fileno=19960423&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="57D61963715D0FE37F0B5928655DE7D2";