Geng Xiusheng,et al.Guideline of radiation protection and safety for low temperature thermo Supply nuclear reactors[J].Chinese Journal of Radiological Medicine and Protection,1996,16(4):260-264
Guideline of radiation protection and safety for low temperature thermo Supply nuclear reactors
Received:January 15, 1996  Revised:February 15, 1996
DOI:
KeyWords:Guideline radiation protection safety low temperature thermo supply reactor
FundProject:国家“八五”重点攻关科技项目
Author NameAffiliation
Geng Xiusheng 100088 北京, 卫生部工业卫生实验所 
郭力生 北京放射医学研究所 
刘原中 清华大学核能技术研究院 
周舜元 100088 北京, 卫生部工业卫生实验所 
陈金娣 100088 北京, 卫生部工业卫生实验所 
吴柏龄 北京放射医学研究所 
鲁华玉 北京放射医学研究所 
曹建主 清华大学核能技术研究院 
石乃芝 北京放射医学研究所 
秦斌 100088 北京, 卫生部工业卫生实验所 
杨玲 北京放射医学研究所 
杨英杰 100088 北京, 卫生部工业卫生实验所 
阎效珊 北京放射医学研究所 
郭芙蓉 100088 北京, 卫生部工业卫生实验所 
Hits: 4260
Download times: 1904
Abstract::
      A proposal on the guideline of radiation protection and safety for a low temperature thermo supply nuclear reactor has been put forward,namely:(1) Weighted population in a 50km radius region should not exceed 106;(2) The radlus of exclusion area is 250m;(3)The radius of restricted development area is 2km;(4)The individual dose(whole body or effective) to publiccaused by release of radioactivity to environmemt during normal operation of a low temperature thermo supply nuclear reactor should not exceed 0.1mSv/a,and the collective dose should not exceed 100man·Sv/a;(5) Indvidual dose(whole body or effective) during an accident of a low temperature thermo Supply nuclear reactor should not exceed 5mSv,and the collective dose should not exceed 1000man·Sv;(6) For a low temperature thermo Supply nuclear reactor during normal operation the release of radioactive effluent should not exceed two-fifths of the value defined in national standard GB6249;(7) The radionuclide concentrationin the water of heating loop should not exceed 0.37Bq/l;(8)Three emergency grades are proposed:namely,emergency standby,plant emergency and site emergency.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12031940  On-line:0

v
Scan QR Code
&et=F854FE67D8A66916127F9F01096047A3AE351BBE155A63805EFB5E7318D495B7703168CF8939D13E7519F5EF2AF165B8D55D0D667C1CD718EA934B8E15DC6BBE1EBEE5557AA2C1BEADCD06D843D3A4980FBB9D0C87207F66C9BB19A4BA276293&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=2CE72A2C6644564AD84F7720FD60BB82&vid=&iid=E158A972A605785F&sid=89AC6B0ADBEA2741&eid=7ABC4505E3960D2B&fileno=19960422&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="2CE72A2C6644564AD84F7720FD60BB82";