Zhao Huiyun,Li Wuling,Rao Yongqing,et al.Mutual comparison between several formulae used for estimating absorbed dose to tritiumincorporated cell nuclei[J].Chinese Journal of Radiological Medicine and Protection,1996,16(4):238-242
Mutual comparison between several formulae used for estimating absorbed dose to tritiumincorporated cell nuclei
Received:November 07, 1995  Revised:April 14, 1996
DOI:
KeyWords:Cell nuclei  tritium  absorbed  dose estimation  formulae
FundProject:
Author NameAffiliation
Zhao Huiyun Department of Basic radiation Medicine, Beijing Medical University, Beijing, 100083 
Li Wuling Department of Basic radiation Medicine, Beijing Medical University, Beijing, 100083 
Rao Yongqing Department of Basic radiation Medicine, Beijing Medical University, Beijing, 100083 
Chen Guanying Department of Basic radiation Medicine, Beijing Medical University, Beijing, 100083 
沈磊 Department of Basic radiation Medicine, Beijing Medical University, Beijing, 100083 
Hits: 2865
Download times: 1643
Abstract::
      The average absorbed dose to cell nuclei due to 3H-TdR incorporation in human lymphocytes was calculated by using different dose formulae on the basis of data obtained from incorporating experiments in vitro.The results showed that there was no significant difference between the nuclear doses estimated by the formulae of Robertson,Rossi and Goodheart.The results came from Apeigot's formula were higher than those from the above-mentioned formulae.A formula improved upon the Apelgot's was proposed.The "mass mean method" also brought about higher results,but by the aid of edge effect coefficient the method was able to give correct results for nuclei with 3μm radius.Ifthe radius of nuclei is larger or smaller than 3μm,abnormal results of mass mean method would emerge.The 0.27 cGy/dis.was just effective for nuclei with 4μm radius.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12032081  On-line:0

v
Scan QR Code
&et=3B288778309D75CB77556564551379BFD5B9995B7AE02636BB030BB13FBED08B3406056B1A2E5CA2776E7F9833FE738A558E821C313D3B8E87E69BBA9CB4AAB6D891A7BC16C271B9023B4135CA1728C2BFAAF600ACD9C942DF304DA7AA033351091D8D60E7C47B5F1E21312284020F12&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=2CE72A2C6644564A258A73FB264EE210&vid=&iid=E158A972A605785F&sid=9CA95D22FC1D537C&eid=0C191C6ECF79047F&fileno=19960411&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="2CE72A2C6644564A258A73FB264EE210";