Xu Guizhen,Li Xiuyi,Gong Shouliang.Effects of low dose radiation on function of peritoneal macrophages in mice[J].Chinese Journal of Radiological Medicine and Protection,1996,16(2):93-95
Effects of low dose radiation on function of peritoneal macrophages in mice
Received:December 12, 1994  Revised:March 16, 1995
DOI:
KeyWords:Irradiation  macrophages  engulfing  digestion.
FundProject:国家自然科学基金
Author NameAffiliation
Xu Guizhen Department of Radiation Biology, Norman Bethune University of Medical Sciences, Changchun, 130021 
Li Xiuyi Department of Radiation Biology, Norman Bethune University of Medical Sciences, Changchun, 130021 
Gong Shouliang Department of Radiation Biology, Norman Bethune University of Medical Sciences, Changchun, 130021 
刘淑春 Department of Radiation Biology, Norman Bethune University of Medical Sciences, Changchun, 130021 
刘树铮 Department of Radiation Biology, Norman Bethune University of Medical Sciences, Changchun, 130021 
Hits: 2480
Download times: 1319
Abstract::
      This study was undertaken to observe the effects of single whole body irradiation with 0, 0.05,0.075,0.15,2.0 and 4.0 Gy of X-rays on the function of peritoneal macrophages from Kunming mice in engulfing and digestion of chicken red blood cells (CRBC). The results showed that the engulfing functions of macrophages on CRBC 3 and 5 days after irradiation with 0.05 and 0.075 Gy increased obviously,and their digestive function after irradiation with 0.075 Gy was significantly higer than that in 0 Gy group. However,their engulfing and digestive functions decreased after the irradiation with 2 and 4 Gy.These results suggest that low dose radiation can stimulate the function of nonspecific immunity while large dose radiation can inhibit it.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9067142  On-line:0

v
Scan QR Code
&et=970261AF74811A5D673BCD6251A9EA6B4F9C3F4B63BC11A27DB76EF7B412BC692C76DD7063F5AB959B724CF038A25FDD130ED03766949947A44DF45CEDA4211109E298A280D87AAB178EA4E97FB81851&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=2CE72A2C6644564AF6075C025F8EEB1C&vid=&iid=0B39A22176CE99FB&sid=39EEF47180459690&eid=C36EC077A8A90308&fileno=19960208&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="2CE72A2C6644564AF6075C025F8EEB1C";