Luo Chengji,Guo Chaohua,Zhou Yanhong,Liu Xin.Effects of interleukin-3 on hemopoietic function after combined radiation-burn injury in mice[J].Chinese Journal of Radiological Medicine and Protection,1996,16(1):28-31
Effects of interleukin-3 on hemopoietic function after combined radiation-burn injury in mice
Received:November 24, 1994  Revised:April 05, 1995
DOI:
KeyWords:Interleukin-3  combined radiation-burn injury  hematopoietic function
FundProject:国家自然科学基金
Author NameAffiliation
Luo Chengji 630038 重庆, 第三军医大学防原医学教研室 
Guo Chaohua 630038 重庆, 第三军医大学防原医学教研室 
Zhou Yanhong 630038 重庆, 第三军医大学防原医学教研室 
Liu Xin 第三军医大学分子遗传教研室 
Hits: 2579
Download times: 73
Abstract::
      Destruction of hemopoietic function is one of the most basic pathologic changes in combined radiation-burn injury.Interleukin-3 exhibits a broad-spectum stimulating effect on proliferation and differentiation for hemopoietic cells.This study was aimed to investigate the effects of interleukin-3 on hmopoietic function after combined radiation-burn injury in mice.The results show that preventing and additionally treating radiation injury or the combined radiation-burn injury with IL-3 have better effects on the stimulation of hematopoiesis in vivo than only preventing or treating with IL-3.This favourable stimulation of hemopoiesis was not only expressed in granulocyte-macrrophage progentors(CFU-GM) or erythroid progenitors(CFU-E, BFU-E), but also in bone marrow stromal elements(CFU-F).Stimulating effect on hemopoiesis was not shown in animals with burn injury in which hemopoietic failures did not appear.The results indicate that excellent prospects are expected by using IL-3 in treating radiation injury or combined radiation-burn injury.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9074656  On-line:0

v
Scan QR Code
&et=970261AF74811A5D9DB3E5BC116F126EAAF0F747D60C4D4161E300FB6A27F7C1CA95D27E990463C07A51D20F59D3CD902AD70076DEF250826D4175BC16FC64089DE71B565A7BF0A4A4AB3E131E1E3EBF7FC7CD9BCC0EF93E0996347D753B28E7&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=8A15F8B0AA0E5323&aid=2CE72A2C6644564AAADC4D5A90402237&vid=&iid=CA4FD0336C81A37A&sid=D3E34374A0D77D7F&eid=4AD960B5AD2D111A&fileno=19960111&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="8A15F8B0AA0E5323"; var my_aid="2CE72A2C6644564AAADC4D5A90402237";