Tu Kaicheng,Cao Zhenshan,Zhu Xiaoxia,et al.Morphometric study of malignant transformation of human embryo lung cells in vitro induced by 60Coγ-rays[J].Chinese Journal of Radiological Medicine and Protection,1995,15(4):255-259
Morphometric study of malignant transformation of human embryo lung cells in vitro induced by 60Coγ-rays
Received:January 20, 1994  Revised:February 22, 1995
DOI:
KeyWords:Human embryo lung cells  transformation  morphometry  radiation effect  dose rate
FundProject:国家自然科学基金
Author NameAffiliation
Tu Kaicheng Institute of Radiation Medicine ,Beijing, 100850 
Cao Zhenshan Institute of Radiation Medicine ,Beijing, 100850 
Zhu Xiaoxia Institute of Radiation Medicine ,Beijing, 100850 
周淑珍 Institute of Radiation Medicine ,Beijing, 100850 
杨素霞 Institute of Radiation Medicine ,Beijing, 100850 
樊飞跃 Institute of Radiation Medicine ,Beijing, 100850 
刘国廉 Institute of Radiation Medicine ,Beijing, 100850 
Hits: 3149
Download times: 1647
Abstract::
      Morhpometric differences of transformed human embryo lung (HEL) cells in vitro induced by 60Coγ-rays at different dose rates were studied by image analysis. Relationship between the morphometric parameters of cells and cellular nuclei on the one hand and the dose rate and irradiation dose on the other hand was analyzed quantitatively. The results show that the area, equivalent diameter and shape factor of cell increased with increasing irradiation doses; so did the area,perimeter,eqivalent diameter of cellular nuclei and ratio of nucleus to plasma. A linear square equation (E=a+bD+c D2)can fit satisfactorily to show the the relationship between dose and effect.These morphometric parameters demonstrated close functional dependent relation to dose rate and irradiation dose, except that the equivalent diameter of cells was related to irradiation dose only. Damage effect on large doses groups was more obvious than that on small dose groups.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12030052  On-line:0

v
Scan QR Code
&et=6B508A615565CB5880DD1EA6EF355AFC3331DA6EBDB22196DFD37A46A72DC240147CF6EEF70E2F16A5F1C071829D0A65CCC64778489B4BF26E459A03640C7CCDB8BEC8EA52F5B5ED3E3D324FF0CA01D1083040AAE4BB59C56A2E2486C1761FF9043F7A6F1283CC55E34523891DE7F45B11E6FE6F71864724&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BBCD5003575B2B5F&aid=57387B4018C200E77787357FB32AF3A3&vid=&iid=E158A972A605785F&sid=627456E7977439A4&eid=0F7768518993EDDE&fileno=19950409&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BBCD5003575B2B5F"; var my_aid="57387B4018C200E77787357FB32AF3A3";